Host Interface
4-66
C156-E205-01EN
4.6.15 RECEIVE DIAGNOSTIC RESULTS command
Table 4.98 RECEIVE DIAGNOSTIC RESULTS command
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (1Ch)
1
Reserved
2
Reserved
3-4
Allocation Length
5-11
Reserved
The RECEIVE DIAGNOSTIC RESULTS command transfers the diagnostic
results indicated by the SEND DIAGNOSTIC command to the host. The
RECEIVE DIAGNOSTC RESULT command must be issued following the
SEND DIAGNOSTIC command. If not issued continuously or if there is no data
to be transferred, the command transfers no data and ends normally.
4.6.16 REQUEST SENSE command
Table 4.99 REQUEST SENSE command
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (03h)
1
Reserved
2-3
Reserved
4
Allocation Length
5-11
Reserved
The REQUEST SENSE command transfers sense data to the host. Sense data
indicates detailed error information on the command whose error was reported
previously. If no error command was reported, SENSE KEY indicates NO
SENSE.
When issuing the REQUEST SENSE command to detect the device status, first
issue the TEST UNIT READY command, then issue REQUEST SENSE.
Allocation Length indicates the length of sense data to be transferred in bytes. If
Allocation Length is 0, the command transfers no data and ends normally.
Summary of Contents for MCJ3230AP
Page 1: ...C156 E205 01EN MCJ3230AP OPTICAL DISK DRIVE PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 5: ......
Page 25: ......
Page 26: ...This page is intentionally left blank ...
Page 48: ...Specifications 2 12 C156 E205 01EN Figure 2 3 Example of alternate processing ...
Page 54: ...Installation Requirements 3 6 C156 E205 01EN Unit mm Figure 3 2 Dimensions ...
Page 55: ...3 2 Mounting Requirements C156 E205 01EN 3 7 Unit mm Figure 3 3 Dimensions without panel ...
Page 164: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 196: ...This page is intentionally left blank ...
Page 198: ......
Page 199: ......