Host Interface
4-40
C156-E205-01EN
In this chapter, unless otherwise specified, the value of data marked as "Reserved"
that is sent from the host is ignored. In addition, unless otherwise specified, 0 is
returned to the data marked as "Reserved" that is sent from the device to the host.
However, if the data marked as "Reserved" is specified for a code value such as
Page Code of the Mode Sense command, unless otherwise specified, Check
Condition is returned.
4.6.1 ERASE command
Table 4.39 ERASE command
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (2Ch)
1
Reserved
2-5
Logical Block Address
6
Reserved
7-8
Transfer Length
9-11
Reserved
The ERASE command erases data of the specified number of blocks from the
specified logical block address.
Logical Block Address specifies the head logical block address from which the
ODD starts writing.
Transfer Length specifies the number of blocks to be transferred and written.
When Transfer Length is specified as 0, the command does not carry out data
transfer. The ERASE command erases no data of the blocks and ends normally.
Summary of Contents for MCJ3230AP
Page 1: ...C156 E205 01EN MCJ3230AP OPTICAL DISK DRIVE PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 5: ......
Page 25: ......
Page 26: ...This page is intentionally left blank ...
Page 48: ...Specifications 2 12 C156 E205 01EN Figure 2 3 Example of alternate processing ...
Page 54: ...Installation Requirements 3 6 C156 E205 01EN Unit mm Figure 3 2 Dimensions ...
Page 55: ...3 2 Mounting Requirements C156 E205 01EN 3 7 Unit mm Figure 3 3 Dimensions without panel ...
Page 164: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 196: ...This page is intentionally left blank ...
Page 198: ......
Page 199: ......