4 - 80
C156-E142-02EN
Table 4.116 Power-on and reset timing
Symbol
Timing parameter
min
max
t10
RESET- pulse width
25 ns
-
t11
Device 0 RESET- negation to BSY bit set to one, release
PDIAG -
-
400 ns
t12
Device 0 release DASP-
-
1 ms
t13
Device 0 sample of DASP-
1 ms
450 ms
t14
Device 0 sample of PDIAG-
1 ms
31 s
t15
Device 1 RESET- negation to BSY bit set to one
-
400 ns
t16
Device 1 assert DASP-
-
400 ms
t17
Device 1 negate PDIAG - if asserted
-
1 ms
t18
Device 1 assert PDIAG-
-
30 s