5.2 Log Parameters
•
Total write errors posted (page 02, code 0002)
Table 5.27 Total write errors posted (page 02, code 0002)
Bit
Byte
7 6 5 4 3 2 1 0
4
5
(MSB)
X'0002' (Parameter code)
(Total Posted Errors)
(LSB)
DU DS TSD
ETC
TMC LBIN LP
6
0 0 0 0 0 0 0 0
7
X'04' (Parameter Length)
8 (MSB)
9
10
Counter Value
11 (LSB)
The Counter Value indicates the count of all posted errors to the interface during
write operations.
Implementation:
If a write error is posted, it will force a save of all error log pages information.
•
Total recoverable write errors posted to INIT (page 02, code 0003)
Table 5.28 Total recoverable write errors posted to INIT (page 02, code 0003)
Bit
Byte
7 6 5 4 3 2 1 0
4
5
(MSB)
X'0003' (Parameter code)
(Total Posted Recoverable Errors)
(LSB)
DU DS TSD
ETC
TMC LBIN LP
6
0 0 0 0 0 0 0 0
7
X'04' (Parameter Length)
8 (MSB)
9
10
Counter Value
11 (LSB)
The Counter Value indicates the count of all posted recovered (01/xx/xx) errors to
the interface during write operations.