4.1 Control/Sense Commands
5) TMC (Threshold Met Criteria)
This field is ignored when "ETC" bit is 0. For LOG SELECT command (See
4.1.15), the HDD accepts this field value of other than "00b", but ignores its
functionality.
6) LBIN
This bit is only valid if the "LP" bit is one. If the "LP" bit is one and this bit is
zero then the list parameter is a string of ASCII graphic codes.
If the "LP" bit is one and this bit is one then the list parameter is a list of
binary information.
7) LP (List Parameter)
"1": The parameter is a data counter.
"0": The parameter is a list parameter.
If these bits are specified by LOG SELECT command, the HDD terminates
normally.
But the HDD's action is not changed.
For LOG SENSE command, these bits always report value defined in each log
page (see Chapter 5).
C141-C013