5.5.4Setting parameters
The user can specify the optimal operation mode for the user system environments by setting the
following parameters with the MODE SELECT or MODE SELECT EXTENDED command:
•
Error recovery parameter
•
Disconnection/reconnection parameter
•
Caching parameter
•
Control mode parameter
With the MODE SELECT or MODE SELECT EXTENDED command, specify 1 for the "SP" bit on
CDB to save the specified parameter value on the disk. This enables the IDD to operate by using the
parameter value set by the user when power is turned on again. When the system has more than one
INIT, different parameter value can be set for each INIT.
When the parameters are not set or saved with the MODE SELECT or MODE SELECT
EXTENDED command, the IDD sets the default values for parameters and operates when power is
turned on or after reset. Although the IDD operations are assured with the default values, the
operations are not always optimal for the system. To obtain the best performance, set the parameters
in consideration of the system requirements specific to the user.
This section outlines the parameter setting procedures. Refer to Chapter 3 of Fibre Channel Interface
Specifications for further details of the MODE SELECT and MODE SELECT EXTENDED
commands and specifying the parameters.
1.
At factory shipment of the IDD, the saving operation for the MODE
SELECT parameter is not executed. So, if the user does not set parameters,
the IDD operates according to the default value of each parameter
2.
The model select parameter is not saved for each Loop ID of but as the
common parameter for all IDs. In the multi-INIT System, parameter setting
cannot be changed for each INIT.
3.
Once parameters are saved, the saved value is effective as long as next
saving operation is executed from the INIT. For example, even if the
initialization of the disk is performed by the FORMAT UNIT command, the
saved value of parameters described in this section is not affected.
4.
When the IDD, to which the saving operation has been executed on a
system, is connected to another system, the user must pay attention to that
the IDD operates according to the saved parameter value if the saving
operation is not executed at installation.
Summary of Contents for MAP3147FC
Page 1: ...C141 E163 01EN MAP3147FC MAP3735FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 6: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 20: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 62: ...Installation Requirements 4 10 C141 E163 Figure 4 10 SCA2 type connector ...
Page 108: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 113: ......
Page 114: ......