Data Format
3-8
C141-E163
Each sector on the track consists of the following fields:
(1)
Gaps (G1, G2, G3)
No pattern is written on the gap field.
(2)
PLO Sync
In this field, pattern X'00' is written.
(3)
Sync Mark (SM1, SM2)
In this field, special pattern is written. This special pattern indicates the beginning of the data field.
(4)
Data field (DATA1-DATA4)
User data is stored in the data field of the sector. The length of the data field is equal to that of the
logical data block which is specified with a parameter in the MODE SELECT command. Any
multiple of 4 between 512 and 528 bytes can be specified as the length.
(5)
BCRC
It is a 4-byte error detection code. Errors in the ID field. Single burst errors with lengths of up to 32
bits for each logical block can be detected.
(6)
ECC
This is the 60-byte code that allows detection and correction of errors in the data field, which is
capable of correcting the single burst error up to 240 bits max. on the fly.
(7)
PAD
A specified length of x‘00’ pattern is written in this field. This field includes the variation by rotation
and circuit delay till reading/writing.
Summary of Contents for MAP3147FC
Page 1: ...C141 E163 01EN MAP3147FC MAP3735FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 6: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 20: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 62: ...Installation Requirements 4 10 C141 E163 Figure 4 10 SCA2 type connector ...
Page 108: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 113: ......
Page 114: ......