![Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive Product/Maintenance Manual Download Page 98](http://html.mh-extra.com/html/fujitsu/man3184mc-enterprise-18-4-gb-hard-drive/man3184mc-enterprise-18-4-gb-hard-drive_product-maintenance-manual_121502098.webp)
C141-E128-01EN
6 - 2
Brief test contents of self-diagnostics are as follows.
a. Hardware function test
This test checks the basic operation of the controller section, and contains following test.
•
RAM (microcode is stored)
•
Peripheral circuits of microprocessor (MPU)
•
Memory (RAM)
•
Data buffer
b. Seek test
This test checks the positioning operation of the disk drive using several seek modes (2 points
seek, 1 position sequential seek, etc.). The positioning operation is checked with confirming
the physical address information by reading the ID field (LBA) from the data block on track 0
after completion of the seek operation to the target cylinder.
c. Write/read test
This test checks the write/read function by using the Internal test space of the disk drive.
(1)
Initial self-diagnostics
When power is turned on, the IDD starts initial self-diagnostics. The initial self-diagnostics
checks the basic operations of the hardware functions.
If an error is detected in the initial self-diagnostics, the LED on the drive front panel blinks. In
this status, the IDD posts the CHECK CONDITION status to all I/O operation requests other than
the REQUEST SENSE command. When the CHECK CONDITION status is posted, the INIT
should issue the REQUEST SENSE command. The sense data obtained with the REQUEST
SENSE command details the error information detected with the initial self-diagnostics.
Even if CHECK CONDITION status and sense data are posted, the LED continues blinking. Only
when the SCSI bus is reset, the TARGET RESET message is issued, or the power is turned off or
re-turned on, this status can be cleared. When this status is cleared, the IDD executes the initial
self-diagnosis again.
Summary of Contents for MAN3184MC - Enterprise 18.4 GB Hard Drive
Page 18: ...This page is intentionally left blank ...
Page 28: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 66: ...C141 E128 01EN 4 14 Figure 4 17 External operator panel connector CN2 ...
Page 124: ...8 8 C141 E128 01EN Figure 8 3 Block diagram of read write circuit ...
Page 130: ...This page is intentionally left blank ...
Page 134: ...This page is intentionally left blank ...
Page 140: ...This page is intentionally left blank ...
Page 145: ......