C141-E128-01EN
4 - 10
(4)
Sequential starting of spindle motors
After power is turned on to the IDD, a large amount of current flows in the +12 VDC line when
the spindle motor rotation starts. Therefore, if more than one IDD is used, the spindle motors
should be started sequentially using one of the following procedures to prevent overload of the
power supply unit. For how to set a spindle motor start control mode, see Subsection 5.3.2.
a) Issue START/STOP commands at more than 12-second intervals to start the spindle motors.
For details of this command specification, refer to SCSI Logical Interface Specifications.
b) Turn on the +12 VDC power in the power supply unit at more than 12-second intervals to start
the spindle motors sequentially.
(5)
Power supply to SCSI terminating resistor
If power for the terminating resistor is supplied from the IDD to other SCSI devices through the
SCSI bus, the current-carrying capacity of the +5 VDC power supply line to the IDD must be
designed with considering of an increase of up to 200 mA.
A method of power supply to the terminating resistor is selected with a setting terminal on the
IDD (MP model only). See Subsection 5.3.2 for this selection.
For the electrical condition of supplying power to the terminating resistor, refer to Subsection
1.4.2 in SCSI Physical Interface Specifications.
(6)
Noise filter
To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the IDD
power supply unit. The specification of this noise filter is as follows:
•
Attenuation: 40 dB or more at 10 MHz
•
Circuit construction: T-configuration as shown in Figure 4.12 is recommended.
Figure 4.12 AC noise filter (recommended)
Summary of Contents for MAN3184MC - Enterprise 18.4 GB Hard Drive
Page 18: ...This page is intentionally left blank ...
Page 28: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 66: ...C141 E128 01EN 4 14 Figure 4 17 External operator panel connector CN2 ...
Page 124: ...8 8 C141 E128 01EN Figure 8 3 Block diagram of read write circuit ...
Page 130: ...This page is intentionally left blank ...
Page 134: ...This page is intentionally left blank ...
Page 140: ...This page is intentionally left blank ...
Page 145: ......