C141-E103-01EN
4 - 8
(4)
Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3
cm from the disk drive. At designing the system cabinet, consider following points.
•
Make a suitable air flow so that the DE surface temperature does not exceed 55°C.
•
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.
Table 4.1
Surface temperature check point
No.
Measurement point
Criteria
1
Center of DE cover
55°C
2
Read channel LSI
83°C
3
VCM/SPM Driver
75°C
4
HDC
85°C
Figure 4.8 Surface temperature measurement points
1
1
1
3
2
4
4
4
3
2
2
3
MAJ3364 Series
MAJ3182, MAJ3091 Series
MAH Series
Summary of Contents for MAH3091MC - Enterprise 9.1 GB Hard Drive
Page 3: ...This page is intentionally left blank ...
Page 19: ...This page is intentionally left blank ...
Page 37: ...This page is intentionally left blank ...
Page 55: ...C141 E103 01EN 4 2 3 175 0 25 Figure 4 1 External dimensions MAH series MC model ...
Page 56: ... 1 LJXUH WHUQDO GLPHQVLRQV 0 VHULHV 03 PRGHO ...
Page 57: ...C141 E103 01EN 4 4 3 175 0 25 Figure 4 3 External dimensions MAJ series MC model ...
Page 58: ... 1 LJXUH WHUQDO GLPHQVLRQV 0 VHULHV 03 PRGHO ...
Page 70: ...C141 E103 01EN 4 17 Figure 4 20 External operator panel connector CN2 ...
Page 81: ...This page is intentionally left blank ...
Page 138: ...C141 E103 01EN 8 15 This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 148: ...This page is intentionally left blank ...
Page 152: ...This page is intentionally left blank ...
Page 157: ......