C141-E103-01EN
6 - 14
Table 6.2
System-level field troubleshooting
Item
Recommended work
DC power cable
Check that the power cable is correctly connected to the disk drive and
power supply unit.
AC and DC power level
Check that the DC voltage is within the specified range (±5%).
Check that the +5 VDC value (pins 3 and 4 of the power connector) is
4.75 to 5.25 VDC.
Check that the +12 VDC supply (pins 1 and 2 of the power connector of
disk drive) is 11.4 to 12.6 VDC.
Electrical noise
Make sure the maximum ripple peak-to-peak value of +5 VDC is within
250 mV and +12 VDC is within 250 mV.
Interface cable connection
Check that the SCSI interface cable is correctly connected between the
disk drive and controller.
Terminating resistors
For a daisy chain connection, check the terminating resistor on the last
disk drive only. For a star-burst connection, check that the terminating
resistor is correctly mounted on all disk drives.
Drive selection address
Check that the disk drive selection address is set correctly.
Plug setup
Check that the jumpers on the PCA are set so that the disk drive and host
computer operate normally. See Section 5.3.
System cables
Check that all system cables are connected correctly.
System diagnostic test
When possible, execute the system level diagnostic routine as explained
in the host computer manual. This gives a detailed report of a possible
fault.
Intermittent or nonfatal errors
Check the AC voltage from the power supply. Check the DC voltage
level at the power connector for the disk drive.
If the AC voltage level is abnormal or there is a lot of electrical noise,
notify the user of the error.
If the DC voltage level is unstable, replace the power supply unit.
If possible, replace the disk drive. If replacing the disk drive does not
eliminate the error, the removed disk drive is probably not faulty. To
continue error analysis, refer to the hardware and software manuals
supplied with the system.
Summary of Contents for MAH3091MC - Enterprise 9.1 GB Hard Drive
Page 3: ...This page is intentionally left blank ...
Page 19: ...This page is intentionally left blank ...
Page 37: ...This page is intentionally left blank ...
Page 55: ...C141 E103 01EN 4 2 3 175 0 25 Figure 4 1 External dimensions MAH series MC model ...
Page 56: ... 1 LJXUH WHUQDO GLPHQVLRQV 0 VHULHV 03 PRGHO ...
Page 57: ...C141 E103 01EN 4 4 3 175 0 25 Figure 4 3 External dimensions MAJ series MC model ...
Page 58: ... 1 LJXUH WHUQDO GLPHQVLRQV 0 VHULHV 03 PRGHO ...
Page 70: ...C141 E103 01EN 4 17 Figure 4 20 External operator panel connector CN2 ...
Page 81: ...This page is intentionally left blank ...
Page 138: ...C141 E103 01EN 8 15 This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 148: ...This page is intentionally left blank ...
Page 152: ...This page is intentionally left blank ...
Page 157: ......