DIAGNOSTIC TESTS AND ERROR CODES
M2488 PRODUCT GUIDE
F-76
CG00000-011503 REV. A
April 1997
Table F-23. Routine 82 - Magnetic Tape Unit Diagnostic Error Codes
ROUTINE
TEST
TITLE
ERROR
CODE
DESCRIPTION
0x82
*
MTU diagnostics routine
0xE0
A DVL card was not detected. This routine
requires that the DTC card be properly con-
nected to a DVL card.
0x82
0x01
MTU diagnostic load execute
table
-
(No error codes specific to this test)
0x82
0x02
MTU diagnostic send execute
table
0x01
The MTU diagnostic parameters were not
successfully downloaded through the Servo
Shared RAM Interface.
0x82
0x03
MTU diagnostic run
0x01
Servo Interface indicated that a servo com-
mand was not accepted
0x02
Servo Interface indicated that an error
occurred while processing the current Servo
Command. Sense information was built.
0x03
The current servo command failed to com-
plete in the allocated time.
0x04
An error occurred during execution of the cur-
rent servo command. Sense information was
built.
0x05
No valid test groups were found.
0x82
0x04
MTU diagnostic retrieve results
table
0x01
An error occurred attempting to retrieve the
MTU diagnostic results through the Servo
Shared RAM Interface.
Table F-24. Routine 83 - Operator Control Panel Diagnostic Error Codes
ROUTINE
TEST
TITLE
ERROR
CODE
DESCRIPTION
0x83
*
All Operator Control Panel tests
0xE0
Operator Control Panel interface to the DTC
card not detected.
0x83
0x01
Operator Control Panel keys test
0x01
RESET switch press not detected in allotted
time.
0x02
RESET switch release not detected in allotted
time.
0x03
UNLOAD switch press not detected in allot-
ted time.
0x04
UNLOAD switch release not detected in allot-
ted time.
0x05
START switch press not detected in allotted
time.
DIA
GNOS
TIC
TES
TS
AND E
R
R
O
R
C
O
DES
Summary of Contents for M2488
Page 1: ...C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE ...
Page 4: ......
Page 64: ......
Page 70: ...DESIGN ARCHITECTURE M2488 PRODUCT GUIDE 2 6 CG00000 011503 REV A April 1997 ...
Page 82: ......
Page 236: ......
Page 366: ...MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE 8 56 CG00000 011503 REV A April 1997 ...
Page 374: ...SENSE KEYS M2488 PRODUCT GUIDE A 2 CG00000 011503 REV A April 1997 ...
Page 480: ...DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE F 80 CG00000 011503 REV A April 1997 ...
Page 522: ...INDEX M2488 PRODUCT GUIDE Index 8 CG00000 011503 REV A April 1997 ...
Page 524: ......
Page 526: ......
Page 527: ......
Page 528: ......