TAPE UNIT PARAMETERS
M2488 PRODUCT GUIDE
5-8
CG00000-011503 REV. A
April 1997
If the DTDC field is non-zero and the Maximum Burst Size is non-zero, the target shall return
CHECK CONDITION status. The sense key will be set to ILLEGAL REQUEST and the additional
sense code set to ILLEGAL FIELD IN PARAMETER LIST.
The DTDC field is reported as changeable on a MODE SENSE command, and the default value is
zero.
8-9
0
The Connect Time Limit field indicates the maximum time, in 100 microsecond
increments, that the target remains connected until it attempts to disconnect. A value
of zero in this field indicates that there is no Connect Time Limit.
The Connect Time Limit field is reported as not changeable on a MODE SENSE
command, and the default value is zero.
10-11
The Maximum Burst Size field indicates the maximum amount of data to be trans-
ferred between SCSI bus disconnects when disconnects are allowed. The value in
this field is multiplied by 512 bytes to signify the maximum amount of data. For
example, a “1” in this field signifies 512 bytes and a “2” signifies 1024 bytes.
A value of zero in this field indicates no limit on the amount of data transferred. The
controller attempts to honor the specified value. However, in no case does the con-
troller transfer only a portion of a record. When reading a compressed tape, the con-
troller does not know how much uncompressed data is produced by a record about
to be transferred. In this case, the compressed record length (rather than the actual
bus transferred size) is used to determine if the maximum burst size is exceeded.
The Maximum Burst Size field is reported as not changeable on a MODE SENSE
command, and the default value is zero.
12
0-1
The Data Transfer Disconnect Control (DTDC) field defines further restrictions on
when a disconnect is permitted. Table 5-9 relates the significance of different values
in this field.
Table 5-9. Data Transfer Disconnect Control
DTDC
DESCRIPTION
00b
Data transfer disconnect control is not used. Disconnect is controlled by the other fields in this page.
01b
A target will not disconnect once the data transfer of a command has started until all data the command
is to transfer has been transferred. The connect time limit and bus inactivity limit are ignored during the
data transfer.
10b
Reserved
11b
A target will not disconnect once the data transfer of a command has started until the command is com-
plete. The connect time limit and bus inactivity limit are ignored once data transfer has started.
Table 5-8. Page 02 - Disconnect/Reconnect Parameters Field Description (Continued)
BYTE
BIT
VALUE
DESCRIPTION
Summary of Contents for M2488
Page 1: ...C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE ...
Page 4: ......
Page 64: ......
Page 70: ...DESIGN ARCHITECTURE M2488 PRODUCT GUIDE 2 6 CG00000 011503 REV A April 1997 ...
Page 82: ......
Page 236: ......
Page 366: ...MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE 8 56 CG00000 011503 REV A April 1997 ...
Page 374: ...SENSE KEYS M2488 PRODUCT GUIDE A 2 CG00000 011503 REV A April 1997 ...
Page 480: ...DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE F 80 CG00000 011503 REV A April 1997 ...
Page 522: ...INDEX M2488 PRODUCT GUIDE Index 8 CG00000 011503 REV A April 1997 ...
Page 524: ......
Page 526: ......
Page 527: ......
Page 528: ......