Chapter 5 Troubleshooting
IP-900E/IP-900D series
58
No. Class
Status
Description
Recommended
action
41.
Are the network settings (IP
address, subnet mask, etc.) on the
control terminal PC correct?
Make correct settings by referring to the PC
user's guide and OS handbook. If this device is
started with the default settings made before
shipment from the factory, see "Section 3.3.1,
"Settings," for the network settings for the
control terminal PC.
42.
Net
w
or
k
Is a reply received in response to a
PING command issued to the IP
address of the device?
If a reply is not received, turn on the power to
the device while holding down the MNT button
to start the system with the default IP address
(10.0.0.1) set before shipment from the factory.
Confirm the IP address. If the problem
persists, check the status on the LAN. For
information on this startup procedure, see
Section 3.6, "Special Use of Cancel Key."
Table 5.1.1 Problem descriptions and recommended actions(IP-900D/IP-900IID)
No. Class
Status
Description
Recommended
action
1
Is the power cable connected?
Make sure that the power cable is properly
connected to the outlet.
2
Power
Power cannot
be turned on.
Is the outlet voltage normal?
Measure the voltage with a tester to confirm that
the voltage is normal.
If another device is connected to the same
outlet, check the operation of the device.
3
The ALM LED
is blinking.
Check the log information from the
browser.
The temperature inside the device
has risen to the critical level, the fan
speed has fallen, or a CF card
access error has occurred.
If the ambient temperature of the device is too
high, make proper arrangements to lower the
ambient temperature. If there is any shielding
material in the installation space, remove it.
If the fan speed is low, the fan needs to be
replaced. Contact a Fujitsu Service Center.
In the case of a CF card access error, restart the
device. If the problem persists, contact a
Fujitsu Service Center. The CF card or the
device needs to be replaced.
4
The ALM LED
is on.
The device is faulty.
Troubleshoot from the control terminal.
(For details, see the software manuals.)
Is the ambient temperature of the
device higher than that in the
specifications?
Adjust the temperature so that the ambient
temperature of the device meets the
specification's condition.
5
Device
The LEDs
excluding LAN
are on.
Is there any shielding material in
the installation space?
Remove the shielding material.
6
Is the port setting correct?
Check the data input-output port setting.
7
Is the data input/output device
operating normally?
Check the operation of the data input/ output
device.
8
Data
Data
communication
is disabled.
Are the device and the
communication destination device
correctly connected?
Check cable connections between the device
and communication destination device and the
cable pin assignments.
Summary of Contents for IP-900 II D
Page 1: ...IP 900E IP 900D IP 900ⅡD Hardware User s Guide ...
Page 2: ... This page is intentionally left blank ...
Page 16: ... This page is intentionally left blank ...
Page 24: ... This page is intentionally left blank ...
Page 46: ... This page is intentionally left blank ...
Page 48: ... This page is intentionally left blank ...
Page 56: ... This page is intentionally left blank ...
Page 60: ...Chapter 4 Cable specifications IP 900E IP 900D series 46 3 Analog AUDIO cable ...
Page 61: ...Chapter 4 Cable specifications IP 900E IP 900D series 47 4 HDMI cable ...
Page 68: ... This page is intentionally left blank ...
Page 78: ... This page is intentionally left blank ...
Page 80: ... This page is intentionally left blank ...
Page 94: ... This page is intentionally left blank ...
Page 95: ...Glossary and Index Glossary 83 Index 86 CE Conformity Information 88 Glossary and Index ...
Page 96: ... This page is intentionally left blank ...
Page 104: ......