CAPACITY COMPENSATION RATE FOR PIPE LENGTH
5.
AND HEIGHT DIFFERENCE
MODEL
: AOU24CL1
Height difference H
1 Indoor unit is upper than outdoor unit.
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
COOLING
Pipe length (m)
5
7.5
10
15
20
25
30
16ft.
25ft.
33ft.
49ft.
66ft.
82ft.
98ft.
Height
difference
H
(m)
Û
1
Indoor unit is
upper than
outdoor unit.
20
66ft.
-
-
-
-
0.951
0.951
0.950
10
33ft.
-
-
0.980
0.966
0.967
0.967
0.966
7.5
25ft.
-
0.988
0.984
0.970
0.971
0.971
0.970
5
16ft.
0.995
0.992
0.988
0.974
0.975
0.975
0.974
0
0ft.
1.003
1.000
0.996
0.982
0.983
0.983
0.982
Û
2
Indoor unit is
under than
outdoor unit
-5
-16ft.
1.003
1.000
0.996
0.982
0.983
0.983
0.982
-7.5
-25ft.
-
1.000
0.996
0.982
0.983
0.983
0.982
-10
-33ft.
-
-
0.996
0.982
0.983
0.983
0.982
-20
-66ft.
-
-
-
-
0.983
0.983
0.982
Summary of Contents for Inverter Halcyon AOU24CL1
Page 1: ...AIR CONDITIONER Wall Mounted type INDOOR OUTDOOR ASU24CL1 AOU24CL1 DESIGN TECHNICAL MANUAL ...
Page 2: ...1 INDOOR UNIT WALL MOUNTED TYPE ASU24CL1 DTR_AS046E_02 2010 12 02 ...
Page 23: ...2 OUTDOOR UNIT SINGLE TYPE AOU24CL1 DTR_AO068E_02 2010 12 02 ...
Page 28: ... 02 04 OUTDOOR UNIT AOU24CL1 OUTDOOR UNIT AOU24CL1 WIRING DIAGRAMS 444 MODEL AOU24CL1 ...
Page 33: ... 02 09 OUTDOOR UNIT AOU24CL1 OUTDOOR UNIT AOU24CL1 SOUND LEVEL CHECK POINT 88888 39 3 8 in 1m ...