SAFETY DEVICES
10.
Protection form
Model
AOU24CL1
Circuit protection
Current fuse
(NEAR THE TERMINAL)
20A 250V
5A 250V
Current fuse
(MAIN PRINTED CIRCUIT
BOARD)
15A 250V
3.15A 250V
Fan motor protection Thermal protection program
OFF : 212±50°F (100±10°C)
ON : 203±50°F (95±10°C)
Compressor
protection
Thermal protection program
(DISCHARGE TEMP.)
OFF : 230°F (110°C)
ON : After 7 minutes
Summary of Contents for Inverter Halcyon AOU24CL1
Page 1: ...AIR CONDITIONER Wall Mounted type INDOOR OUTDOOR ASU24CL1 AOU24CL1 DESIGN TECHNICAL MANUAL ...
Page 2: ...1 INDOOR UNIT WALL MOUNTED TYPE ASU24CL1 DTR_AS046E_02 2010 12 02 ...
Page 23: ...2 OUTDOOR UNIT SINGLE TYPE AOU24CL1 DTR_AO068E_02 2010 12 02 ...
Page 28: ... 02 04 OUTDOOR UNIT AOU24CL1 OUTDOOR UNIT AOU24CL1 WIRING DIAGRAMS 444 MODEL AOU24CL1 ...
Page 33: ... 02 09 OUTDOOR UNIT AOU24CL1 OUTDOOR UNIT AOU24CL1 SOUND LEVEL CHECK POINT 88888 39 3 8 in 1m ...