background image

En-4

OPERATING MANUAL

Program timer (combined use of the ON timer and the OFF timer)

You can set an integrated ON–OFF or OFF–ON timer as follows:

ON–OFF  Set the ON timer 

fi

 rst. 

Then set the OFF timer by the air conditioner starts opera-

tion controlled with the ON timer earlier set.

OFF–ON  Set the OFF timer 

fi

 rst. 

Then set the ON timer by the air conditioner stops opera-

tion controlled with the OFF timer earlier set.

The timer that is set later starts counting down after the counting 
down of the preceding timer is 

fi

 nished.

Note:

If you change the setting value for the timer after the program timer is 
set, the counting down of the timer will be reset at that moment.

11  SLEEP TIMER button

Each time you press the button, the time changes as follows:

1.0

2.0

3.0

5.0

7.0

CANCEL

hours

9.0

• Set the time while the 

 indicator on the remote controller display 

is blinking.

  To repeat the timer, press the button when the indicator is not 

displayed.

To help you to fall asleep comfortably and prevent excessive warming 
or cooling in sleep, the SLEEP timer controls the temperature setting 
automatically in accordance with the set time shown as follows. The 
air conditioner completely turns off after the set time has elapsed.

In COOL or DRY mode

Set 
temperature

30 min.

2 °F (1 °C)

2 °F (1 °C) 4 °F (2 °C) 6 °F (3 °C) 8 °F (4 °C)

4 °F (2 °C)

In HEAT mode

1 hour

1.5 hour

Set time

Set time

1 hour

Note for TIMER settings:

Any interruption of the power supply, such as a blackout or cutting off 
of a circuit breaker, makes the set internal clock go wrong. In such a 
case, the TIMER indicator on the indoor unit blinks, and you need to 
readjust the setting.

12  °F/°C button

• Used for changing the temperature unit. (Initial setting: °F )
• When you press this button, the displayed temperature unit switches 

to “°C”, and returns to “°F” when you press it again.

• When you press this button, press it gently by using the tip of a 

ballpoint pen or other small object in correct direction as shown in 
this 

fi

 gure.

13  ECONOMY button

Starts or stops ECONOMY operation that saves more electricity 
consumption than the other operations with a conservative adjustment 
of the room temperature.
When you press the button, the ECONOMY indicator on the indoor 
unit turns on.
• In COOL mode, the room temperature will be adjusted at a few 

degree higher than the de

fi

 ned temperature. 

  In HEAT mode, the room temperature will be adjusted at a few 

degree lower than the de

fi

 ned temperature.

• Especially in COOL mode, you can have improved dehumidi

fi

 cation 

without signi

fi

 cantly lowering the room temperature.

Notes:

• In COOL or HEAT mode, the maximum output of this operation is 

approximately 70 % of usual air conditioning operation.

• This operation cannot be performed during temperature monitoring 

by AUTO mode.

14  POWERFUL button

Starts POWERFUL operation that enables quick cooling down or 
warming up of the room. 
When you press the button to start the POWERFUL operation, the 
indoor unit emits 3 short beeps.

POWERFUL operation is automatically turned off in the following 
situations:
• Adjusted room temperature reached to the de

fi

 ned temperature in 

temperature setting in COOL, DRY, or HEAT mode.

• 20 minutes have passed after 

fi

 nishing the POWERFUL operation 

mode setting.

It is not turned off automatically during setting of the POWERFUL 
operation.

Notes:

• The air

fl

 ow direction and the fan speed are controlled automatically.

• This operation cannot be performed simultaneously with ECONOMY 

operation.

To return to normal operation, press the button again. Then the indoor 
unit emits 2 short beeps.

15  Remote controller display

In this section, all the possible indicators are displayed for description.  
In actual operation, the display is linked with the button operation, and 
only shows the necessary indicators for each setting.

16  Signal transmitter

Aim to signal receiver of the indoor unit properly.
• Signal transmit indicator   on the remote controller display shows 

that signal from the remote controller is being transmitted.

• Operating range is approximately 7 m.
• You will hear a beep if the transmitted signal has been sent properly.  

If there is no beep, press the button on the remote controller again.

 Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost 
may form on the outdoor unit during the heating operation, and 
it could reduce the operating performance of the product. 
For frost protection, a microcomputer-controlled automatic 
defrost function is equipped in this air conditioner. 
If frost forms, the air conditioner will temporarily stop, and 
defrost circuit will operate brie

fl

 y (maximum of 15 minutes.)

OPERATION indicator on the indoor unit blinks during this 
operation. 
If frost forms on the outdoor unit after the heating operation, the 
outdoor unit will stop automatically after it operates for a few 
minutes. Then the automatic defrosting operation starts.

 Auto-restart function

In event of power interruption such as a blackout, the air 
conditioner stops once. But it restarts automatically and 
performs previous operation when the power supply is resumed.

If any power interruption occurs after the timer is set, counting 
down of the timer will be reset. 
After the power supply is resumed, the TIMER indicator on the 
indoor unit blinks to notify you that there has been a timer fault. 
In such a case, reset the timer for your opportune time.

Malfunctions caused by other electrical devices:

Use of other electrical appliances such as an electric shaver or 
nearby use of a wireless radio transmitter may cause the malfunction 
of the air conditioner. 
If you encounter such a malfunction, turn off the circuit breaker once. 
Then turn it on again, and resume operation by using the remote 
controller.

Remote Controller Overview and Operations

9332621013_OM.indb   4

9332621013_OM.indb   4

9/21/2012   1:23:47 PM

9/21/2012   1:23:47 PM

Summary of Contents for Halcyon ASVG09LLCA

Page 1: ...r plug or by turning on or off the circuit breaker Do not use inflammable gases near the unit Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate the unit with air filters installed Ensure that ...

Page 2: ...UTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal may not be transmitted properly In such a case consult the store that you purchased the product 7 ECONOMY in...

Page 3: ...uttons Set desired temperature Temperature setting range AUTO 64 88 F 18 30 C COOL DRY 64 88 F 18 30 C HEAT 60 88 F 16 30 C Temperature control is not available in FAN mode 4 FAN button Controls the fan speed AUTO HIGH MED LOW QUIET When AUTO is selected the fan speed is automatically adjusted according to the operation mode 5 SET button Adjusts the vertical airflow direction 6 SWING button Starts...

Page 4: ...tarts POWERFUL operation that enables quick cooling down or warming up of the room When you press the button to start the POWERFUL operation the indoor unit emits 3 short beeps POWERFUL operation is automatically turned off in the following situations Adjusted room temperature reached to the defined temperature in temperature setting in COOL DRY or HEAT mode 20 minutes have passed after finishing ...

Page 5: ...he intake grille b b b a a 4 Press 4 places on the intake grille to close it completely Care and Cleaning Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the air...

Page 6: ...operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 4 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET th...

Reviews: