background image

En-8

8.  OTHER OPERATIONS

8.1.  Powerful operation

In the Powerful operation, the air conditioner will operate at maximum 

power and strong airflow to cool down or warm up the room quickly.

)

)

Press 

 to activate/deactivate the Powerful operation.

When activated, the indoor unit will emit 2 short beeps.

When deactivated, the indoor unit will emit 1 short beep.

The Powerful operation will be turned off automatically in the following 

situations:

•  The Powerful operation runs for a certain amount of time and the 

room temperature reaches the set temperature in the Cooling, Dry, 

or Heating mode.

•  20 minutes after the Powerful operation has started.

NOTES:

• 

The airflow direction and the fan speed are controlled automatically.

•  The Powerful operation cannot be performed simultaneously with 

Economy operation.

•  The Powerful operation overrides the following operations. If 

the following operations are set, they will start after the Powerful 

operation finishes.

 -Outdoor Unit Low Noise operation

 -Energy Saving program

•  If the wired remote controller (optional) is connected, this function is 

restricted.

8.2.  Outdoor Unit Low Noise operation

The Outdoor Unit Low Noise operation lowers noise from the outdoor 

unit. During this operation, the rotation number of the compressor 

decreases and the outdoor unit fan rotates slowly.

)

)

Press 

 to activate/deactivate the Outdoor Unit Low 

Noise operation.

9.  SETTINGS ON INSTALLATION

9.1.  Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can 

specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to 

operate them separately, set the custom code (4 selections possible).

NOTES: 

If custom codes is different between the indoor unit and the 

remote controller, the indoor unit cannot receive a signal from 

the remote controller.

How to set the remote controller custom code

1. 

 Press 

 until only the clock is displayed on the remote 

controller display.

2. 

 Press  down

 

 

for more than 5 

seconds.

The current custom code will be 

displayed (initially set to A).

3. 

Press 

 to change the 

custom code between A↔B↔C↔D.

* Match the custom code on the display 

to the air conditioner custom code.

4. 

Press 

 again.

The custom code will be set.  

The display  will return to the clock 

display.

•  To change the air conditioner custom code, contact an authorized 

service personnel (initially set to A).

•   If you do not press any buttons for 30 seconds after the custom 

code is displayed, the display returns to the clock display. In this 

case, repeat the setting from step 2.

•  Depending on the remote controller, the custom code may return 

to A when replacing the batteries. In this case, reset the custom 

code as necessary. If you do not know the air conditioner custom 

code, try each code until you find the code which operates the air 

conditioner.

 

Details on Demand Response mode

DR mode

Description of operation in this mode

DR mode 1

Compressor off.

DR mode 2

electrical energy consumption in 30 minutes:
50 % or less 

(compared with rated energy consumption)

DR mode 3

electrical energy consumption in 30 minutes:
75 % or less

(compared with rated energy consumption)

NOTES:

•  During the DR mode, the cooling or heating performance may be 

reduced.

•  During the DR mode, only the following operations are valid.

 -

Turning off the operation by 

 -

Off timer operation

•  The Powerful operation is performed within the operable range of 

the DR mode.

•  During the DR mode, the Filter sign will not display.

•  Timer setting error indicator will be prioritized over the DR mode 

indicator.

If you have operational issues:

(1)  Contact your electricity supplier to check whether they are activating 

the DR mode.

(2)  Is the air conditioner under the Demand controlling?

Yes

Contact your electricity supplier.

No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to 

your warranty card.) 
or

• Visit our website (www.fujitsugeneral.com.au).

While the Outdoor Unit Low Noise operation is activated, 

 

on the remote controller is displayed.

The setting is preserved even if the air conditioner is turned off.

NOTES: 

•  This operation cannot be performed simultaneously with the Fan 

mode, Dry mode, and Powerful operation.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

8.3.  10 °C Heat operation

10 °C Heat operation maintains the room temperature at 10 °C so as to 

prevent the room temperature to drop too low.

)

)

Press 

 to activate the 10 °C Heat operation.

The indoor unit will emit 1 short beep and [   ] indicator on the 

indoor unit will turn on.

)

)

Press 

 to turn off the air conditioner. 

 ] indicator will turn off.

NOTES:

•  During the 10 °C Heat operation, only 

 and 

 

 are valid.

•  When the room temperature is warm enough, this operation will not 

perform.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

Summary of Contents for Halcyon ASUG09-12LMAS

Page 1: ...tions codes installation operation manuals before the installation maintenance or service of this product AIR CONDITIONER MODEL Wall Mounted Type OPERATING MANUAL Before using this product read these instructions thoroughly Also keep this manual for future reference together with the installation manuals for the indoor and outdoor units PART No 9387602029 02 Please write down the model name Refer ...

Page 2: ...duct or the power source to prevent any electrical hazards This product shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater This product shall be stored in a well ventilated area Be aware that refrigerants may not contain an odour This product shall be stored so as to prevent mechanical damage ...

Page 3: ...ects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this product to avoid personal injury when you maintain the unit Do not stand on unstable steps when operating or cleaning this product It may ov...

Page 4: ...7 Activates or deactivates the Economy operation Activates or deactivates the Energy saving program that uses the human sensor For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For Outdoor Unit Low Noise operation Refer to page 8 Activates or deactivates the Outdoor Unit Low Noise operation Remote controlle...

Page 5: ...tting to the next step Returns the timer or clock setting to the previous step By pressed down activates or deactivates the wireless LAN control Refer to page 12 Adjusts the value of the timer or clock settings Starts the clock setting After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction...

Page 6: ...ain 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lo...

Page 7: ...ed remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28 C Wake up Leave for work Come back home Go to sleep Saturday No timer settings Sunday Program 1 Program 2 Program 3 Progr...

Page 8: ...cts infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When the room temperature is high and the difference with people s body temperature is small Such as when the temperature is 30 C or higher in summer When someone in the room do not move for a long time When ...

Page 9: ...k display To change the air conditioner custom code contact an authorized service personnel initially set to A If you do not press any buttons for 30 seconds after the custom code is displayed the display returns to the clock display In this case repeat the setting from step 2 Depending on the remote controller the custom code may return to A when replacing the batteries In this case reset the cus...

Page 10: ... handle disconnect the two lower tabs and pull out Air filter handle Hooks 2 places 3 Remove the dust in either of the following ways Cleaning with vacuum cleaner Washing with mild detergent and warm water After washing dry the air filters thoroughly in shade 4 Replace the air filters Align the sides of the air filter with the panel and push in fully Make sure to the two lower tabs are returned to...

Page 11: ...owing Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and transferring that heat to the indoor unit As a result the operating performance is reduce...

Page 12: ...ser registration 1 Open the installed mobile app 2 Register the user with either a smartphone or tablet PC by following the instructions in the create an account section of the mobile app Step 3 Installing W LAN adapter CAUTION Be sure to turn off the power supply of the air conditioner when installing or removing this product to avoid the risk of electric shock Do not put fingers sticks etc in th...

Page 13: ...y 3 Press 4 Select using on the remote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case...

Page 14: ...eries Operation is delayed after restart Has the power supply turned from Off to On suddenly In this case the compressor will not operate for about 3 minutes to prevent a blowout of the fuse Immediately stop operation and turn off the electrical breaker in following cases Then consult authorized service personnel The problem persists even if you perform these checks or diagnostics On the indoor un...

Page 15: ... Check that the power to the wireless router is on There is a possibility that the W LAN adapter is not properly connected to the wireless router 11 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the W LAN adapter is being updated During the air conditioner registration pairing of W LAN adapter 12 Restricted function 11 Manual Auto operat...

Page 16: ......

Reviews: