Did you fan the documents before loading them in the ADF paper chute (feeder)?
Solution
Fan the documents.
For details, refer to
Preparation (When Loading Multiple Documents) (page 42)
●
Have the documents just been printed out from a copy machine or a laser printer?
Solution
Fan the documents a few times to remove static electricity.
For details, refer to
Preparation (When Loading Multiple Documents) (page 42)
●
Is there a document remaining in the ADF?
Solution
Remove the document from the ADF.
For details, refer to
When a Paper Jam Occurs (page 103)
●
Are the pad unit and pick roller installed correctly?
Solution
Install the pad unit and pick roller correctly.
For details, refer to
Replacing the Pad Unit (page 96)
Replacing the Pick Roller (page 99)
.
●
Are the pad unit and pick roller clean?
Solution
Clean the pad unit and pick roller.
For details, refer to
Cleaning the Inside of the Scanner (ADF) with a Cloth (page 89)
.
●
Are the pad unit and pick roller worn out?
Solution
Start up the Software Operation Panel to check the counters for the pad unit and pick roller, and if
necessary, replace the pad unit and pick roller.
For details, refer to
Checking the Sheet Counters (page 162)
For details about replacing the pad unit and pick roller, refer to
Replacing the Pad Unit (page 96)
and
Replacing the Pick Roller (page 99)
●
Are you using the scanner at an altitude of 2,000 m or higher?
Solution
Enable [High Altitude Mode] in the Software Operation Panel.
For details, refer to
Scanning at High Altitude [High Altitude Mode] (page 180)
If the scanner is being used on level ground lower than 2,000 m with [High Altitude Mode] enabled,
overlapped documents may not be detected.
Troubleshooting
127
Summary of Contents for FI-800R
Page 1: ...P3PC 6672 01ENZ2 FUJITSU Image Scanner fi 800R Operator s Guide ...
Page 21: ... Inside ADF Scanner Overview 21 ...
Page 153: ...4 Click the OK button The password is set Scanner Settings Software Operation Panel 153 ...
Page 155: ...The password is cleared Scanner Settings Software Operation Panel 155 ...
Page 157: ...4 Click the OK button The password is set Scanner Settings Software Operation Panel 157 ...
Page 201: ...Outer Dimensions The outer dimensions are as follows Unit mm in Appendix 201 ...