Chapter 9 Operational Settings
184
*1: Displayed when using fi-7260 or fi-7280.
Removing Shadows/Streaks that Appear around
the Scanned Image
[Page Edge Filler (ADF)]/[Page Edge Filler (FB)]
(fi-7260/fi-7280)
Depending on the condition of the documents that you scan,
the shadow of the document may appear as black streaks.
In that case, you can improve the image quality around the
edges of the document by using the "Page Edge Filler"
function to fill in the edges.
1
Start up the Software Operation Panel.
For details, refer to
"9.1 Starting Up the Software Operation Panel"
2
From the listing on the left, select [Device Setting 2]
[Page Edge Filler (ADF)] or [Page Edge Filler (FB)].
Vertical
magnification
Adjustment
Description
Unit
Select [Flat bed] (*1) or [ADF] as the target for
vertical magnification adjustment.
Vertical
magnification
Adjustment
(Sub: length)
Adjusts the vertical (length) magnification.
The value can range from -3.1 to +3.1% (in
increments of 0.1).