98
ETERNUS
LT20
S2
Tape Library Error Codes
Troubleshooting
DA
In Wellness Test the barcode
reader has read different barcode
data for the same cartridge label
Check barcode on scratch
cartridge and run 'library
Health Check' again. If the
error recurs, contact
technical support
DB
External cooling fan error (fan
motion has stopped).
The sub code indicates which
drive sled fan is affected
Check if the indicated fan is
operational and not
obstructed. If the error
persists, contact technical
support
F0
Drive Over temperature
Condition
Sub code 01: drive sled #1
Check ambient temperature
conditions and check all fans,
after several occurrences
contact technical support
F1
Drive Communication Error,
library controller has lost commu-
nication to drive
Sub code 01: drive sled #1
Retry operation; if not
successful contact technical
support
F2
Drive Sled not present
Sub code 00: drive sled #1
Retry operation; if not
successful contact technical
support
F3
Drive Hardware Error
Cycle Power, after several
occurrences contact
technical support
F4
Drive Load Timeout
Drive has run in a timeout while
loading a tape
Retry operation; if not
successful contact technical
support
F5
Drive Unload Timeout
Drive has run in a timeout while
unloading a tape
Retry operation; if not
successful contact technical
support
Error Code Description
User Action