background image

Encore

®

 and Eclipse

®

 Series

Owner’s Manual

MDE-3893P

Summary of Contents for eclipse

Page 1: ...Encore and Eclipse Series Owner s Manual MDE 3893P ...

Page 2: ...467 Transac System 1000 and PAM 1000 E105106 Dell DHM Minitower E165027 G SITE and Passport Systems National Conference of Weights and Measures NCWM Certificate of Conformance CoC Gilbarco pumps and dispensers are evaluated by NCWM under the National Type Evaluation Program NTEP NCWM has issued the following CoC CoC Product Model CoC Product Model 02 019 Encore Nxx 02 036 Legacy Jxxx 02 020 Eclips...

Page 3: ...Last Transaction 15 Displaying Pump Totals for Encore Eclipse Units 16 Grade Number Reference Chart 17 Operating the Units 19 Console Mode Two wire 19 Standalone Mode 19 4 Preparing to Service Units 21 Important Considerations for DEF Dispensers 21 Important Considerations for Units with Ecometers 22 Important Considerations When Changing Fuel Types 23 Dispensing Gasoline Ethanol Blends 24 Importa...

Page 4: ...Information 44 Changing the Receipt Paper in the M00317A00X Printer 45 Changing the Receipt Paper in USB Printer M04119A001 48 Changing the Receipt Paper in USB Sliding Printer M06972A001 51 Changing the Receipt Paper in USB Sliding Printer for Encore S Series Enhanced Bezel M07885A001 55 Cleaning the CRIND Device in the M00317A00X Printer 59 Clearing Paper Jams in USB Printer M04119A001 59 Cleari...

Page 5: ...gramming Encore and Eclipse units Preparing the units for service Maintaining the units Related Documents Document Number Title GOLD Library MDE 3802 Encore Eclipse Site Prep Manual Encore and Eclipse Encore and Eclipse Installers Site Prep MDE 3985 Encore Installation Manual Encore and Eclipse Encore and Eclipse Installers MDE 3986 Eclipse Installation Manual Encore and Eclipse Encore and Eclipse...

Page 6: ...tion FCC Federal Communications Commission FF Flexible Fuels IFSF International Forecourt Standards Forum LCD Liquid Crystal Display LON Local Operating Network MOC Major Oil Company MPD Multi Product Dispenser NEC National Electrical Code NFPA National Fire Protection Association OSHA Occupational Safety and Hazard Administration PIN Personal Identification Number PPP Programmable Pump Preset PPU...

Page 7: ...r safety and the safety of others to understand the procedures before beginning work Follow the Regulations Applicable information is available in National Fire Protection Association NFPA 30A Code for Motor Fuel Dispensing Facilities and Repair Garages NFPA 70 National Electrical Code NEC Occupational Safety and Hazard Association OSHA regulations and federal state and local codes All these regul...

Page 8: ... for example address front back of building and so on Nature of accident for example possible heart attack run over by car burns and so on Age of victim for example baby teenager middle age elderly Whether or not victim has received first aid for example stopped bleeding by pressure and so on Whether or not a victim has vomited for example if swallowed or inhaled something and so on IMPORTANT Oxyg...

Page 9: ... do not always stop product flow Take precautions to avoid igniting fuel Do not allow starting of vehicles in the area Do not allow open flames smoking or power tools in the area Do not expose yourself to hazardous conditions such as fire spilled fuel or exposed wiring Call emergency numbers WARNING Spilled fuels accidents involving pumps dispensers or uncontrolled fuel flow create a serious hazar...

Page 10: ...Page 6 MDE 3893P Encore and Eclipse Series Owner s Manual December 2011 Important Safety Information This page is intentionally left blank ...

Page 11: ...e 500 Units PRESS 91 PRICE PER UN IT U S REGULA TION S PRESS 89 PRICE PER UN IT U S REGULA TION S PRESS 87 PRICE PER UN IT U S REGULA TION S Nozzle CRIND Display CIM Door Lock Hose Door Lock Boot Area Main Display Breakaway Shear Valves and Unions behind Lower Panel not shown Swivel PPU Display and Grade Select Buttons Lower Panel CRIND Device Printer Cash Acceptor Available but not shown Totalize...

Page 12: ...Encore 550 Unit Main Display CIM Door Lock CRIND Display Cash Acceptor CRIND Device Printer Door Lock Lower Panel Breakaway for all Encore units is located near the hose casting at the top of the Pump Dispenser for units without Hose Retrievers For units with Hose Retrievers the breakaway is located near the Nozzle The VR hose nozzle information and FCC label are found on the right side when facin...

Page 13: ...eries refer to Additional Security in Encore S Series Units on page 27 Figure 3 3 Encore S Series Unit Breakaway Hose Main Door CRIND Display Manager s Keypad not shown Located behind the Main Door Card Reader Nozzle Brand Advertising Panel Static Electricity Health and Fire Warnings recommended location Printer Door Lock CRIND Device Printer CRIND or PPP Keypad Security Latch not shown Located be...

Page 14: ...pse Series Owner s Manual December 2011 Americans with Disabilities Act ADA Requirements To meet the reach requirements as specified by the Americans with Disabilities Act the island of the dispenser must not be higher than 6 tall IMPORTANT INFORMATION Figure 3 4 ADA Requirements 42 48 6 ...

Page 15: ...nk is not Installed Underground 25 0 1 0 Urea Tank 160 0 6 3 Skid Common to Both Urea Tank and Dispenser Urea Inlet 1 BSPP Female Fitting on the Dispenser 2000 0 6 5 of Hose Length Exposed 115 7 4 6 160 0 6 3 308 0 12 1 29 9 1 2 Typical Skid Tank Install Insulation and or Heating Required Use solid or foam non water absorbing insulating materials suitable for outdoor use ...

Page 16: ...Boot Area Hydraulic Access Door Lock Breakaway Swivel Lower Panel filter access Door Lock Main Display Card Reader Serial Plate Scanner PPU Display and Grade Select Buttons Filters Junction Box Shear Valves and Unions behind Lower Panel not shown Oven Door Lower Panel CRIND Device Printer Lock not shown Branding Advertising Panel Backlit Oven Door Lock not shown CRIND Keypad Manager s Keypad not s...

Page 17: ...ar Codes J 2000 N 2004 T 2008 K 2001 P 2005 U 2009 L 2002 R 2006 W 2010 M 2003 S 2007 X 2011 To determine the date code on an Encore or Eclipse unit refer to the following tables Understanding Model Codes The Model Numbers are located as shown in Figure 3 1 on page 7 Figure 3 2 on page 8 Figure 3 3 on page 9 and Figure 3 6 on page 12 For Encore 300 500 550 units the Model Number uses a two letter ...

Page 18: ...rade Single hose Pump J Multi hose Blender 0 3 Grade Blender Dispenser 1 3 Grade Blender Pump 2 4 Grade Blender 1 Dispenser 3 4 Grade Blender 1 Pump 4 3 2 Grade Blender Dispenser L X 1 Blender 0 2 1 Grade Blender Dispenser 1 3 1 Grade Blender Dispenser 2 4 1 Grade Blender Dispenser 3 3 1 1 Grade Blender Dispenser 4 2 1 Grade Blender Pump 5 3 1 Grade Blender Pump 6 4 1 Grade Blender Pump N X 0 Blen...

Page 19: ...vailable in an Eclipse unit Eclipse Units E X X Eclipse G Single hose MPD 0 3 Grade L X 1 Blender 4 Hose 0 2 1 Grade Blender Dispenser 1 3 1 Grade Blender Dispenser 2 4 1 Grade Blender Dispenser 3 5 1 Grade Blender Dispenser N X 0 Blender 2 Hose 0 2 0 Grade Blender Dispenser 1 3 0 Grade Blender Dispenser 2 4 0 Grade Blender Dispenser 3 5 0 Grade Blender Dispenser Example A serial plate stamped GM ...

Page 20: ...Programming Manual 2 For Encore S Series units to identify Side 1 of the unit see Figure 3 3 on page 9 The Manager s Keypad is as shown in Figure 3 7 Figure 3 7 Manager s Keypad 1 4 7 CLEAR 2 5 8 0 3 6 9 F1 F2 ENTER TOTAL VOL TOTAL Manager s Keypad Note To enter the Command Codes required to place the pump dispenser in Standalone mode or to program prices directly at the unit refer to Standalone M...

Page 21: ...ons in the following table to display pump totals for Encore and Eclipse units Grade Number Reference Chart To Press Result Display totals Total for Money Vol Total for Volume Side digit flashes Select side 1 Side 1 A 2 Side 2 B Side digit flashes Select grade ENTER and 1 8 for grades 1 8 Grade digit flashes Toggle between side and grade ENTER Toggles flashing digit between side and grade digit Ex...

Page 22: ...ti hose 1 Bl 1 2 3 6 4 1 Bl 1 2 3 4 6 Encore 500 S Dual 1 Quad 1 2 MPD 1 2 3 3 0 Bl 1 2 3 6H Bl 1 2 3 4 Grade MPD 1 2 3 4 5 0 Bl 1 2 3 4 5 3 1 Bl 1 2 3 6 3 0 Bl 1 2 3 Multi hose Bl 1 2 3 MPD 1 2 3 4 Single hose 1 2 3 4 4 0 Bl 1 2 3 4 5 0 Bl 1 2 3 4 5 2 1 Bl 1 2 6 3 1 Bl 1 2 3 6 Multi hose 1 Bl 1 2 3 6 4 1 Bl 1 2 3 4 6 Eclipse 2 0 Bl 1 2 MPD 1 2 3 3 0 Bl 1 2 3 4 0 Bl 1 2 3 4 5 0 Bl 1 2 3 4 5 2 1 Bl...

Page 23: ... a pre authorized mode where a sale is automatically allowed or in an authorization mode where a sale requires initiation by a cashier To operate a unit in authorization mode proceed as follows Note Step 1 can occur before or after steps 2 and 3 1 Authorize the unit at the console 2 Remove the nozzle and lift the pump handle if required 3 Select the grade and or payment form if required 4 Dispense...

Page 24: ...Introducing the Encore Eclipse Series Operating the Units Page 20 MDE 3893P Encore and Eclipse Series Owner s Manual December 2011 This page is intentionally left blank ...

Page 25: ...approved modifications and kits WARNING Important Considerations for DEF Dispensers Applicable during Installation and Operation of the Dispenser DEF freezes at approximately 11 5 C 11 F Power to the dispenser and heater must always remain ON in cold weather If power is lost and the temperature drops below this point the system must be inspected for freeze damage before restart For sites that expe...

Page 26: ... Contaminated DEF must be disposed off in an environmentally safe manner Do not dump DEF in storm sewers or any location where the fluid or its constituents may enter a waterway DEF is much heavier than fuels such as gasoline Be careful to avoid injury when lifting heavier Prover Cans by using proper safe lifting techniques When stored at temperatures above 37 C 100 F DEF may break down into ammon...

Page 27: ...ASTM standards for Biodiesel fuels Mixes of diesel with cooking oils other plant or animal derived oils and so on are not considered Biodiesel Use of such mixes may void warranty on the hydraulic components of the unit 4 Review the latest copy of the unit s warranty statement regarding use of the fuel 5 Certain fuels especially fuels enhanced with alcohol when first used in tanks previously contai...

Page 28: ...RMATION Important Requirements for E85 Units The following equipment and materials are required to properly service the E85 units UL listed E85 Hose Q13486 VeyanceSM Flexsteel Futura Ethan All for E85 Veyance Flexsteel Futura for E25 Note Extended Reach hoses not available for the E85 applications UL listed E85 Nozzle M11298 OPW 21GE Note Approved for use with the E85 dispensers as required under ...

Page 29: ... electronic units write down and report any error codes displayed Note For information on recording and clearing error codes refer to Error Codes on page 29 Description of the Problem Provide the ASC CSC with a complete and accurate description of the problem including all symptoms and error codes Ensure that you give the service personnel as complete and accurate information as possible It will h...

Page 30: ...management or service people when required A sign out system can be used to track who last used the keypad 5 Suggest that the station monitor pump total and station total reports comparatively Theft can be noted as fuel dispensed will still be recorded in pump totals although not in station totals if a thief use the Manager s Keypad When this will not prevent the theft that has already occurred it...

Page 31: ... door bezel See Figure 4 1 on page 28 An improved design that does not enable a person to open the main door without first removing the lower panel door An option to install hinge sensors that will send an alert to the POS whenever the main lower panel doors are opened To optimally utilize the additional security features installed in the Encore S series units proceed as follows 1 Close and lock t...

Page 32: ...re of any lock changes or added locks in order to service the unit The keys must be available to the ASCs Important Installation Information To ensure that your equipment provides safe and reliable operation verify the following Hose breakaways for drive off protection must be installed For breakaways to properly function the pumps must be anchored to the island with bolts Dispensers and some self...

Page 33: ...rding Error Codes Error codes provide an excellent service and troubleshooting tool for ASCs CSCs and will ensure that the ASC CSC brings the correct part to the site for a quick repair Record all error codes and provide the list to your ASC CSC The ASC CSC uses these codes to diagnose and repair unit problems which results in less down time Clearing Error Codes In some cases you can permanently c...

Page 34: ...vice an Encore or Eclipse pump dispenser yourself Only a Gilbarco trained ASC CSC must service an Encore or Eclipse pump dispenser Servicing an Encore or Eclipse pump dispenser incorrectly could result in severe injury or death WARNING To receive specialized training for servicing Encore and Eclipse units contact an ASC CSC or distributor Training may be available locally or at various regional ce...

Page 35: ... important to your customer and you The following recommendations are in addition to those found in the sections that follow and Important Safety Information on page 3 1 Do not allow the customer to use damaged units or broken components with sharp edges 2 Do not allow the customer to use units with missing doors or panels or with doors open 3 Ensure that the adequate and readable instructions are...

Page 36: ...des instructions for scheduling two types of maintenance inspections General inspections Component inspections Note This section does not include special inspections such as those required when changing fuel types For those requirements refer to Important Considerations When Changing Fuel Types on page 23 Safety Warnings You are performing inspections and maintenance in a potentially dangerous env...

Page 37: ...y missing or damaged warning labels Gilbarco also strongly recommends that ASCs CSCs periodically inspect the equipment as outlined in the next subsection Component Inspections To schedule component inspections refer to the following table Generally the station owner must only inspect for damage or problems with the units For safety reasons several tasks in the following table including all repair...

Page 38: ...e is more than one inch of play on one side of belt then tighten the belts by tightening the idler pulley against the belt If there is excessive play then replace the belt with the next shorter length belt 1 1 Upon receiving a customer complaint Replacing printer paper Refer to the instructions in Changing the Receipt Paper in the M00317A00X Printer on page 45 or Changing the Receipt Paper in USB ...

Page 39: ...osion or electrical shock could result if you continue to use a damaged pump dispenser WARNING 2 Inspect each hose for the following wear or damage Bulges Cracks Cuts Flattened spots Reinforcement showing Soft spots Splits Weaknesses Tears 3 Consult the hose manufacturer for any additional inspections required Note If repair is required call an ASC CSC CAUTION Do not attempt to make these repairs ...

Page 40: ... attempt to make these repairs yourself Doing so could result in severe injury or death WARNING Owner Inspect ASC CSC only Repair and test Once a week or as notified about a potential problem Nozzles and boot area 1 Inspect nozzles for the following Damage Leaks Loose nozzle spouts Missing parts such as retainer springs and splash guards CAUTION If you find a leak stop using the pump dispenser and...

Page 41: ... and test Once a week or after drive offs Breakaways 1 Inspect breakaways for secure connection to hose and for any leaks CAUTION If you find a leak stop using the pump dispenser and contact your local ASC CSC Fire explosion or electrical shock could result if you continue to use a damaged pump dispenser WARNING 2 Consult the breakaway manufacturer for any additional required inspections Notes 1 I...

Page 42: ...ck of periodic cleaning are not covered by warranty Owner CAUTION Do not use a pressure washer to clean the pump dispenser CAUTION Once a month Bulbs Eclipse only Where bulbs are used verify if all light box bulbs are illuminated Owner Inspect ASC CSC only Repair and test CAUTION To avoid injury when inspecting the bulbs use a safe and sturdy non conductive fiberglass step ladder Follow ladder man...

Page 43: ...Owner Inspect ASC CSC only Repair and test CAUTION To prevent injury when inspecting self contained units equipped with pumps and electric motors do not place your hands near the belts pulleys or motors Do not allow anyone to use either side of the pump when inspecting Block the pump dispenser off or lock the nozzle to the nozzle hook WARNING CAUTION If you find a leak stop using the pump dispense...

Page 44: ... M05194B001 cleaning kit Be careful not to scratch the display Do not use an abrasive cleaner or glass cleaner or detergent that contains ammonia Ammonia will damage plastic display windows and door materials Owner Every six months Inspect and lubricate Shear Valves To check valve operation perform the following tasks 1 Trip the valve 2 Authorize the hose at the console if required 3 Lift the oper...

Page 45: ...s yourself Doing so could result in severe injury or death WARNING Every six months Nozzle hooks and shafts 1 Lubricate with silicone grease if required 2 Check for damage 3 Ensure that the locking tab locator is not broken The locking tab locator helps hold the nozzle in the nozzle boot and enables the station owner to lock the nozzle boot with a clasp padlock Note If repair is required call an A...

Page 46: ...itial calibration settings Owner arranges for service ASC CSC tests and re calibrates if required For Units Equipped with DEF Once a week especially during cold weather DEF Hose Retriever and Nozzle Door Mechanism Verify if the hose retrieves properly Verify if the nozzle door opens and closes properly From a half way lifted position the door must close completely unassisted after the nozzle has b...

Page 47: ... the large blue colored mounting screws pins that are found only on the M04119A001 and M06972A001 printers Figure 5 1 USB Printer with the Blue Mounting Pins Blue Mounting Screws Avoid contacting the gears on the side of the printer with fingers or hair as it could result in an injury CAUTION CAUTION When the units are wet or when it rains avoid changing paper for units without overhead canopies I...

Page 48: ...w To order printer paper refer to the following table Vender Type Part No Printer Type Moore Wallace Customer Service 1 800 416 8151 Blank Roll 4 M04809B012 M04119A001 USB M00317A00X Printer Low Paper Marks 4 M04809B014 M04119A001 USB M00317A00X Printer Nakagawa Mfg USA 1 800 609 0608 Blank Roll 4 N60125BN M04119A001 USB Low Paper Marks 4 N60125DN M04119A001 USB Moore Wallace Customer Service 1 80...

Page 49: ...Printer Cover Chute Chute Opening Paper Release Lever Paper Bucket Avoid touching any wires or circuit boards during paper replacement as static electricity from your fingers may damage the unit CAUTION To replace the receipt paper in the M00317A00X printer proceed as follows 1 Remove the paper roll core 2 Raise cover over printer head Figure 5 3 Printer Cover Opening Cover Raised over Printer Hea...

Page 50: ...2011 3 Pull the paper release lever towards you Figure 5 4 Paper Release Lever Releasing Paper Release Lever 4 Inspect and remove any paper from the printer chute paper shards in the printer chute can cause a subsequent printer jam Figure 5 5 Paper between the Rollers All Paper Shards to be removed from the Printer Chute ...

Page 51: ...ped cutter and out of the chute exit at the front of the dispenser Note The paper must run straight into the chute Straighten and center the paper as required when feeding Figure 5 6 Paper Feed Paper straightened and centered when fed into the Inlet and Chute 6 Push the paper release lever completely in the forward direction away from you Figure 5 7 Paper Release Lever Locking Paper Release Lever ...

Page 52: ...aps may lead to paper jams later Figure 5 8 Printer Cover Closing Printer Cover in its Closed Position 8 Tear the excess paper at the chute opening Changing the Receipt Paper in USB Printer M04119A001 Figure 5 9 USB Printer Blue Pin Paper Bucket Chute Avoid touching any wires or circuit boards during paper replacement as static electricity from your fingers may damage the unit CAUTION ...

Page 53: ...sent Figure 5 10 Paper Removal Paper must be removed properly to prevent paper jamming Note In Encore S series the printer is installed in an inverted manner as you open the printer door as shown in Figure 5 11 Apart from the way in which the printer is installed the procedure for changing the receipt printer paper remains as explained in this section Figure 5 11 Printer in the Encore S Series Uni...

Page 54: ... pulling the paper to cleanly remove the paper from the paper feed path Figure 5 12 Paper Removal Trigger Decal Remove Paper Trigger Decal Trigger 4 Place the new roll of paper in the paper bucket For orientation see Figure 5 13 Figure 5 13 Paper Feeding into the Printer Feed the paper into the printer as shown Paper Resting in Paper Bucket Right Blue Pin ...

Page 55: ...er 2011 Page 51 Periodic Maintenance Requirements Maintaining Units 5 Feed the paper into the printer inlet following the direction of arrows on the printer Note If the gears rattle when loading the paper press trigger and feed the paper simultaneously The paper will automatically feed through the printer after the initial feed is done manually Changing the Receipt Paper in USB Sliding Printer M06...

Page 56: ...rapped inside the printer the printer automatically reverses the last short receipt left from the paper roll Remove such receipts along with the paper roll core if present Figure 5 15 Paper Removal Paper must be removed properly to prevent paper jamming Figure 5 16 Printer in the Encore S Series Unit Printer Control Module Avoid touching any wires or circuit boards during paper replacement as stat...

Page 57: ...ate the paper removal trigger on the right side of the printer This is located directly under the Remove Paper trigger decal For the exact location of the trigger see Figure 5 17 3 Press the trigger when gently pulling the paper to completely remove the paper from the paper feed path Figure 5 17 Paper Removal Trigger Decal Trigger ...

Page 58: ...inter as shown Prevent your fingers or hair from coming into contact with the gears on the side of the printer as it could result in an injury CAUTION Gears on the Side of the Printer Right Blue Pin 5 Feed the paper into the printer inlet following the direction of arrows on the printer Note If the gears rattle when loading the paper press trigger and feed the paper simultaneously The paper will a...

Page 59: ...A001 To change the receipt paper in the printer proceed as follows Note The USB Sliding Printer for Encore S Series E CIM M07885A001 is capable of holding a receipt paper roll of 6 inches 1 Insert the printer key and turn it to the left to open the printer door Figure 5 19 Inserting the Printer Key 2 Open the printer door and pull out the slide completely Figure 5 20 Opening the Door and Pulling o...

Page 60: ...MDE 3893P Encore and Eclipse Series Owner s Manual December 2011 3 Pull the empty paper spindle from the cable clamp Note The unit is shipped with the spindle held by the cable clamp Figure 5 21 Pulling the Paper Spindle i ii Figure 5 22 Spindle Spindle Lanyard ...

Page 61: ...Periodic Maintenance Requirements Maintaining Units 4 Insert the spindle in a new paper roll and slide it into the spindle slot with the paper feeding from over the top Figure 5 23 Inserting a New Paper Roll i ii iii 5 Remove any small pieces of paper behind the printer head ...

Page 62: ... in ramp as a guide Note Ensure that the paper is fully fed before you proceed If the paper is not fed check if the paper is jammed Figure 5 24 Feeding Paper into the Printer i ii 7 Push the printer slide back in and feed the paper through the slot Close the printer door and turn the key to the right to lock it Figure 5 25 Pushing the Printer Slide i ii 8 Pull to tear paper ...

Page 63: ... Manually advance the cleaning card through the roller bars using the round feed knob near the paper release lever 4 Replace the paper roll and re install the receipt paper Follow the instructions in Changing the Receipt Paper in the M00317A00X Printer on page 45 Clearing Paper Jams in USB Printer M04119A001 Avoid using tools for prying printer parts or using excessive force to clear jams This cou...

Page 64: ...ease trigger is on the right side of the printer Figure 5 27 Printer Head Release Trigger Printer Head Release Trigger 3 Tear paper at the paper feed and at the paper chute 4 Gently pull the paper through the module until it is completely removed Leave no shards in the unit especially in the printer chute Note Rotate the gears to release the shards if required 5 Lower the module back on the paper ...

Page 65: ... excessive force to clear jams This could result in permanent damage to the printer CAUTION To clear a paper jam proceed as follows 1 Release the right blue pin by pulling it upward and tip the Printer Control Module forward to expose the jam Figure 5 29 Printer Control Module Printer Control Module Right Blue Pin Released 2 Press the printer head release trigger on the right side of the printer d...

Page 66: ...Place the Printer Control Module back and push the right blue pin back in place Special Maintenance Instructions Cleaning and Detailing the Unit Materials Required Safety glasses Flexible rubber gloves Concentrated Simple Green all purpose cleaner Soft bristle nylon brush Spray bottle filled with water Empty spray bottle to use with prepared cleaning mixture White cotton cloths Nu Finish car polis...

Page 67: ... the units being cleaned 2 Wear safety glasses and flexible rubber gloves 3 In the empty spray bottle prepare a mixture of one 1 part Concentrated Simple Green cleaner to 10 parts water Do not spray the cleaning mixture and water in or onto the card reader receipt printer cash acceptor or electronic display area as it may damage the equipment and will not be covered by warranty CAUTION 4 Spray the...

Page 68: ...e a mixture of one 1 part Concentrated Simple Green cleaner to one 1 part water 2 Using a new clean white cloth apply the Nu Finish polish to the cloth and apply the polish to the painted or metal surfaces of the unit Note For difficult to remove ground in dirt apply Nu Finish polish to the soft bristle nylon brush and rub the surface 3 Wipe surface of the unit with a clean white cloth 4 Remove ba...

Page 69: ...the cars the device protects against gasoline being spilled and a resulting fire and it minimizes damage to the pump dispensers in the event of a drive off and stops fuel flow through the separated hose C CIM Customer Interface Module the portion of the electronics through which the dispenser interfaces with the customer for example displays and card readers CIM Door Customer Interface Module Door...

Page 70: ...d year of manufacture DEF It is a clear colorless non toxic non flammable non combustible liquid It is made up of 32 5 urea with the balance distilled or deionized water Urea and water are completely miscible and do not separate in storage DEF is mildly corrosive Dispenser A device that uses an STP in the storage tank to move fuel from the storage tank Display Main Refer to Main Display on Glossar...

Page 71: ...rp edges Grade Level of fuel such as unleaded or premium Graphite Lubricant Type of lubricant used on the door locks of units H Hose Outlet Castings Fuel discharge port on the unit where the hose is attached to the unit Hose Retriever Device option at the unit that retracts and pulls the hose close to the unit after the customer has completed fueling Hydraulic Connections Any fuel handling hardwar...

Page 72: ...urrent transaction Manager s Keypad An input device consisting of a separate grid of numerical and function keys arranged for efficient data entry located behind the locked CIM door on the unit Meter Device in the unit that measures fuel flow MOC CRIND device System that uses a single data loop to communication through the G SITE system to both CRIND devices and the unit Mode of Operation Refer to...

Page 73: ...Keypad and some electrical components of the unit P Personal Identification Number PIN Password used by the Station Manager to program the unit different PINS are used for different levels of programming Price Per Unit PPU The price of each unit of gasoline dispensed Programmable Pump Preset PPP Feature that allows customers or attendants to preset the dollar or volume amount of a transaction befo...

Page 74: ... pump Submersible Turbine Pump STP Submersible turbine pump in underground storage tank UST Swivels A fastening that permits the free turning of attached parts to the unit T Two wire Mode A communication mode with the unit where authorization and payout occur at the console V Vapor Hoses Multi wall hoses that reduces the amount of fuel vapor that escapes into the atmosphere when a customer is disp...

Page 75: ...19 Operation Standalone mode 19 Two wire mode 19 P Parts Replacing 29 Performing General and Component Maintenance Inspections 32 Personnel Emergency informing 4 Printer Cleaning Card Q13400 59 Printer Paper Ordering Information 44 Printer Paper Installing 45 48 pumps dispensers 1 Q Q13400 Printer Cleaning Card 59 R Receipt Paper Installing 45 48 Replacement parts 29 S Safety Maintenance 32 Safety...

Page 76: ...f Veyance Technologies Inc Futura is a trademark of Veyance Technologies Inc Nu Finish is a registered trademark of Reed Union Corporation PetroClear is a registered trademark of Champion Laboratories Inc Simple Green is a registered trademark of Corporate Sunshine Makers Inc Teflon is a registered trademark of E I du Pont de Nemours and Company UL is a registered trademark of Underwriters Laborat...