Error messages
A26361-D1567-Z121-1-6319
English - 35
Missing or invalid NVRAM token
Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.
Monitor type does not match CMOS - RUN SETUP
Correct the entry for the monitor type in the
Main
menu of the
BIOS Setup
.
On Board PCI VGA not configured for Bus Master
In the
BIOS Setup
, in the
Advanced
menu, submenu
PCI Configuration
, set the
Shared PCI Master
Assignment
entry to
VGA
.
One or more RDRAM devices are not used
One or more RDRAM devices have bad architecture/timing
One or more RDRAM devices are disabled
Contact your system administrator or contact our customer service centre.
Operating system not found
Check the entries for the hard disk drive and the floppy disk drive in the
Main
menu and the
entries for
Boot Sequence
submenu of the
BIOS Setup
.
Parity Check 1
Parity Check 2
Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.
Previous boot incomplete - Default configuration used
By pressing function key
F2
you can check and correct the settings in
BIOS Setup
. By
pressing function key
F1
the system starts with incomplete system configuration. If the
message is still displayed, please contact your sales outlet or customer service centre.
Real time clock error
Call the
BIOS Setup
and enter the correct time in the
Main
menu. If the message is still
displayed, please contact your sales outlet or customer service centre.
Service Processor not properly installed
The server management controller has not been correctly installed. If the message is still
displayed, please contact your sales outlet or customer service centre.
Storage Extension Group = xy
Configuration error, x Storage Extensions(s) found, configured are y
SE(s).
Device List: k1, k2 ...
The specified number of storage expansion units (SEs) in the
BIOS Setup
menu
Server - Storage
Extensions - Number of connected SE
is incorrect. Check how many SEs within the group are
connected at the server and change the setting in
BIOS Setup
. Check whether you have
assigned the same device ID twice.
xy = Group number
x = Number of SEs found on the communication bus
y = Number of SEs entered in
Number of connected SE
k1, k2 ... = Device ID of the storage extensions found
Summary of Contents for D1567
Page 1: ...Technisches Handbuch Technical Manual Mainboard D1567 Deutsch English Français answers2 ...
Page 3: ......
Page 8: ......
Page 10: ......