BX630 S2
Operating Manual
33
Installation and Operation
Control and Connection Panel
1
Voltage/Selection indicator (two-color LED)
Dark:
The BX600 S2 or BX600 S3 basic unit is off, 5 V standby voltage
is not present, or the server blade is not installed properly.
Glows green:
Server blade is running.
Glows orange:
Server blade is off but basic unit is running (5 V standby voltage is
present).
Flashes green:
Server blade is switched on and selected for identification, or this
server blade is in a critical state.
Flashes
orange:
Server blade is switched off and selected for identification, or this
server blade is in a critical state.
Flashes green-
orange
Server blade is in standby mode (ACPI function) or in a critical
state.
Flashes green-
dark-orange
Server blade is in standby mode (ACPI function) and selected for
identification, or this server blade is in a critical state.
2
On/Off button fully compatible with the Advanced Configuration Power Interface
(ACPI)
If you press the On/Off button when the BX600 S2 or BX600 S3 basic unit is on (5 V
standby voltage is present) and the server blade is switched off, the
power_up
command is sent to the management blade and the server blade is switched on.
If you press the On/Off button for less than 4 seconds when the server blade is
running, the
power_off
command is sent to the management blade and the server
blade is switched off by the management blade (
graceful shutdown
).
If you press the On/Off button for more than 4 seconds when the server blade is
running, the server blade is switched off immediately.
3
KVM/MP error indicator (two-color LED)
Dark:
KVM has not been activated for this server blade.
Glows green:
KVM has been activated for this server blade.
Flashes
orange:
KVM has not been activated for this server blade, and this blade
has been deactivated to save energy.
Flashes green-
orange:
KVM has been activated for this server blade, and this blade has
been deactivated to save energy.
4
KVM button (keyboard/video/mouse)
Pressing this button switches the keyboard, monitor and mouse to this server blade.
5
I/O status of the optional I/O module (green LED)
I/O
Dark:
System is off or signal synchronization has failed.
Green:
System is switched on and online.