2.2. Special tools for R410A

Tool name

Change from R22 to R410A

Gauge manifold

Pressure is high and cannot be measured with a R22 

gauge. To prevent erroneous mixing of other refrigerants, 

the diameter of each port has been changed.

It is recommended to use gauge with seals -0.1 to 5.3 MPa  

(-1 to 53 bar) for high pressure.

-0.1 to 3.8 MPa (-1 to 38 bar) for low pressure.

Charge hose

To increase pressure resistance, the hose material and base 

size were changed. (R410A)

Vacuum pump

A  conventional  vacuum  pump  can  be  used  by  installing  a 

vacuum pump adapter.

(Use of a vacuum pump with a series motor is prohibited.)

Gas leakage detector

Special gas leakage detector for HFC refrigerant R410A.

Copper pipes

It is necessary to use seamless copper pipes and it is desirable that the amount of residual 

oil is less than 40 mg/10 m. Do not use copper pipes having a collapsed, deformed or 

discolored portion (especially on the interior surface). Otherwise, the expansion value or 

capillary tube may become blocked with contaminants.

As an air conditioner using R410A incurs pressure higher than when using R22, it is neces

-

sary to choose adequate materials. 

 WARNING

•  Do not use the existing (for R22) piping and flare nuts.

If the existing materials are used, the pressure inside the refrigerant cycle will rise and 

cause failure, injury, etc. (Use the special R410A materials.)

•  Use (refill or replace with) specified refrigerant (R410A) only.  Use of unspecified refrig

-

erant can cause product malfunction, burst, or injury.

•  Do not mix any gas or impurities except specified refrigerant (R410A).  Inflow of air or 

application of unspecified material makes the internal pressure of the refrigerant cycle 

too high, and may cause product malfunction, burst of piping, or injury.

 WARNING

•  For appropriate working of the air conditioner, install it as written in this manual.

•  To connect indoor unit and outdoor unit, use air conditioner piping and cables available 

through your local distributor. This manual describes proper connections using such 

installation set.

•  Do not turn on the power until all work has been completed.

 CAUTION

This manual describes how to install the indoor unit only. To install the outdoor unit, (if 

any), refer to the installation manual included in each product.

•  Be careful not to scratch the air conditioner when handling it.

•  After installation, explain correct operation to the customer, using the operating manual.

2.3. Accessories

The following installation accessories are supplied. Use them as required.

Name and Shape

Q’ty

Name and Shape

Q’ty

Operating Manual

1

Cloth tape

1

Installation Manual  

(This manual)

1

Tapping screw (Large)

8

Wall hook bracket

1

Tapping screw (Small)

2

Remote controller

1

Air cleaning filter

2

Battery

2

Filter holders

2

Remote controller holder

1

Drain hose insulation

1

The following items are necessary to install this air conditioner. (The items are not includ

-

ed with the air conditioner and must be purchased separately.)

Name 

Q’ty

Name 

Q’ty

Connection pipe assembly

1

Wall cap

1

Connection cable (4-conductor)

1

Saddle

1 set

Wall pipe

1

Drain hose

1

Decorative tape

1

Tapping screws

1 set

Vinyl tape

1

Sealant

1

2.4. Optional parts

Refer to each installation manual for the method of installing optional parts.

Parts name

Model name

Application

Wired Remote Controller *

UTY-RVN*M

For air conditioner operation

Wired Remote Controller **

UTY-RNR*Z1

For air conditioner operation

Wired Remote Controller **

UTY-RLR*

 For air conditioner operation

Simple Remote Controller *

UTY-RSN*M

For air conditioner operation

Communication kit

UTY-XWNX

For the installation of optional parts

Communication kit

UTY-TWRX

For the installation of optional parts

External connect kit

UTY-XWZX

For control input/output port

External input and output PCB *** UTY-GXXB

For connecting external devices

PCB kit

UTY-XCSXZ1

For the installation of optional parts

* Optional communication kit (UTY-XWNX) is necessary for the installation.

** Optional communication kit (UTY-TWRX) is necessary for the installation.

*** Optional PCB kit (UTY-XCSXZ1) is necessary for the installation.

3.  GENERAL SPECIFICATION

This INSTALLATION MANUAL briefly outlines where and how to install the air conditioning system. 

Please read over the entire set of instructions for the indoor and outdoor units and make sure all 

accessory parts listed are with the system before beginning.

3.1. Type of copper pipe and insulation material

 CAUTION

Refer to the installation manual of the outdoor unit for description of the length of 

connecting pipe or for difference of its elevation.

Gas pipe size (thickness) [mm]

Liquid pipe size (thickness) [mm]

Ø

 15.88 (5/8 in.)

Ø 

9.52 (3/8 in.)

 CAUTION

•  Wrap heat insulation around both of the gas pipe and the liquid pipe.  

No heat-insulation work or incorrect heat-insulation work may cause water leaks.

•  In a reverse cycle model, use heat insulation with heat resistance above 120 °C.

•  If expected humidity of the installation location of refrigerant pipes is higher than 70 

%, wrap the heat insulation around the refrigerant pipes.  

If the expected humidity is between 70 % and 80 %, use heat insulation that has  

thickness of 15 mm or more.  

If the expected humidity is higher than 80 %, use heat insulation that has thickness 

of 20 mm or more.

•  Using of thinner heat insulation than specified above may cause a condensation on 

the surface of the insulation.  

•  Use heat insulation with thermal conductivity of 0.045 W/(m•K) or less, at 20 °C.

3.2. Additional materials required for installation

A. Refrigeration (armored) tape

B. Insulated staples or clamps for connecting wire (See your local electrical codes.)

C. Putty

D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping

4.  ELECTRICAL REQUIREMENT

The indoor unit is powered from the outdoor unit. Do not power indoor unit from separate 
power source.

 WARNING

Standard for electrical wiring and equipment differs in each country or region. Before you 

start electrical working, confirm related regulations, codes, or standards.

Cable

Conductor size [

mm

2

]

Type

Remarks

Connection cable

1.5

Type 60245 IEC 57 3 cable + Earth (Ground), 

1 Ø 230 V

Max. Cable Length: Limit voltage drop to less than 2%. Increase cable gauge if voltage 

drop is 2% or more.

9387082050_IM.indb   2

12/10/2015   13:33:20

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Summary of Contents for ASYG36LMTA

Page 1: ... Leakage Circuit Breaker ELCB CAUTION This product is not explosion proof and therefore should not be installed in explosive atmosphere To avoid getting an electric shock never touch the electrical components soon after the power supply has been turned off After turning off the power always wait 5 min utes or more before you touch the electrical components This product contains no user serviceable...

Page 2: ...r 1 Saddle 1 set Wall pipe 1 Drain hose 1 Decorative tape 1 Tapping screws 1 set Vinyl tape 1 Sealant 1 2 4 Optional parts Refer to each installation manual for the method of installing optional parts Parts name Model name Application Wired Remote Controller UTY RVN M For air conditioner operation Wired Remote Controller UTY RNR Z1 For air conditioner operation Wired Remote Controller UTY RLR For ...

Page 3: ...The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could still receive noise under some signal conditions If children under 10 years old may approach the unit take preventive measures so that they cannot reach the unit Install the indoor unit on the wall where the height from the floor is more than 1 8 m 6 INSTALLATION WORK...

Page 4: ...xagonal wrench 4 mm at opposite side to insert the drain cap till the drain cap contacts the tip of the drain cock No gap Hexagonal wrench Drain cock Drain cap CAUTION Insert the drain hose and drain cap into the drain port making sure that it comes in contact with the back of the drain port and then mount it If the drain hose is not connected properly leaking will occur For left piping and left r...

Page 5: ... using the specified tightening method Otherwise the flare nuts could break after a prolonged period causing refrigerant to leak and generate hazardous gas if the refrigerant comes into contact with a flame Connect the piping so that the control box cover can easily be removed for servicing when necessary In order to prevent water from leaking into the control box make sure that the piping is well...

Page 6: ...tallation may cause a fire When fixing the connection cable with the cable clamp always fasten the cable at the plastic jacket portion but not at the insulator portion If the insulator is chafed electric leakage may occur Always connect the earth ground wire Improper earthing grounding work can cause electric shocks Do not use the earth ground screw for the indoor unit to the outdoor unit unless i...

Page 7: ...der to a wall pillar etc with the tapping screw Remote controller holder fixing Remote controller mounting Remote controller holder Tapping screw small 1 Set Remote controller 2 Down 12 OPTIONAL KIT INSTALLATION This air conditioner can be connected with the following optional kits Wired remote controller Simple remote controller External connect kit External input and output PCB 9 FRONT PANEL REM...

Page 8: ...umber selection 3 Press the TEMP buttons to select the set ting value Press the 10 C HEAT button to switch between the left and right digits 4 Press the MODE button once to send the function set ting information Please confirm the beeping sound 5 Next please press Start Stop button once to fix the function setting Please confirm the beeping sound 6 Press the RESET button to cancel the function set...

Page 9: ...n be selected Factory setting Setting Description Function Number Setting Value Operation Stop mode1 46 00 Setting forbidden 01 Forced stop mode 02 Operation Stop mode 2 03 Room temperature sensor switching Aux To use the temperature sensor on the wired remote controller only change the setting to Wired remote controller 01 This function will only work if the function setting 42 is set at Both 01 ...

Page 10: ...uto switch error 4 1 Room temp sensor error 4 2 Indoor unit Heat Ex Middle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 8 Intake grille error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputer...

Reviews: