background image

En-1

P/N 9332621006

Português

EλληvIkά

Italiano

Español

Français

Deutsch

English

Türkçe

Русский

AIR CONDITIONER
Wall Mounted Type

OPERATING MANUAL

Before using this product, read these instructions thoroughly and keep this manual for future reference.

Safety Precautions

To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply 

following safety precautions.

Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:

WARNING

CAUTION

This mark warns of death or serious injury.

This mark warns of injury or damage to property.

 This mark denotes an action that is PROHIBITED.

 This mark denotes an action that is COMPULSORY.

WARNING

• This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not 

play with the appliance.

• This unit contains no user-serviceable parts. Always consult 

authorized service personnel for repairing, installation, and 

relocation of this product.

  Improper installation or handling will cause leakage, electric 

shock, or fire.

• In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 

disconnect all the power supply by turning off the electrical 

breaker or disconnecting the power plug. Then consult 

authorized service personnel.

• Take care not to damage the power supply cable.

  If it is damaged, it should only be replaced by authorized 

service personnel.

• In the event of refrigerant leakage, be sure to keep away 

from fire or any flammables, and consult authorized service 

personnel.

• If you see lightning or hear thunder, there might be a 

lightning strike.

  To prevent electric shock hazard, turn off the air conditioner 

by using the remote controller, and do not touch the unit or 

the power plug during thunderstorm.

• Do not install the unit in area filled with mineral oil such as a 

factory or area containing a large amount of splashed oil or 

steam such as a kitchen.

• Do not start or stop the operation of this product by inserting 

or pulling out the power plug, or by turning on or off the 

circuit breaker.

• Do not use inflammable gases near the unit.
• Do not expose yourself directly to the cooling airflow for 

many hours.

• Do not insert your fingers or any other objects into outlet 

port, open panel, or intake grille.

• Do not operate with wet hands.

CAUTION

• Provide occasional ventilation during use.
• Always operate the unit with air filters installed.
• Ensure that any electronic equipment is at least 1 meter 

away from either the indoor unit or outdoor unit.

• Unplug the power supply cable when not using the indoor 

unit for an extended period.

• After long period of use, check whether the installation stand 

does not deteriorate to prevent the unit from falling down.

• The airflow direction and the room temperature should be 

carefully considered when you use this product in a room 

with infants, children, elderly or sick persons.

• Do not place vase or water container on the unit.
• Do not place any other electrical products or household 

belongings under indoor unit or outdoor unit.

  Dripping condensation from the unit might get them wet, and 

may cause damage or malfunction of your property.

• Do not expose the unit directly to water.
• Do not use this product for preservation of food, plants, 

animals, precision equipment, art work, or other objects. This 

may cause quality deterioration of those items.

• Do not expose animals or plants to the direct airflow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable to disconnect the plug.
• Do not touch the aluminum fins of heat exchanger built-in 

the indoor or outdoor unit to avoid personal injury when you 

install or maintain the unit.

• Do not direct the airflow at fireplaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator fins.
• Do not climb on, place objects on, or hang objects from the unit.

Contents

Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-2
Remote Controller Overview and Operations ..................En-3
Care and Cleaning...........................................................En-5
Troubleshooting ...............................................................En-6

Summary of Contents for asyg35llcr

Page 1: ...uring thunderstorm Do not install the unit in area filled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inflammable gases near the unit Do not expose yourself directly to the cooling ai...

Page 2: ...ntrol signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal may not be transmitted properly In such a case consult the store that you purchased ...

Page 3: ...ture Temperature setting range AUTO 18 30 C COOL DRY 18 30 C HEAT 16 30 C Temperature control is not available in FAN mode 4 FAN button Controls the fan speed AUTO HIGH MED LOW QUIET When AUTO is selected the fan speed is automatically adjusted according to the operation mode 5 SET button Adjusts the vertical airflow direction 6 SWING button Starts or stops automatic swing of the vertical airflow ...

Page 4: ...ton Starts POWERFUL operation that enables quick cooling down or warming up of the room When you press the button to start the POWERFUL operation the indoor unit emits 3 short beeps POWERFUL operation is automatically turned off in the following situations Adjusted room temperature reached to the defined temperature in temperature setting in COOL DRY or HEAT mode 20 minutes have passed after finis...

Page 5: ...intake grille b b b a a 4 Press 4 places on the intake grille to close it completely Care and Cleaning Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the air fi...

Page 6: ...nal parts of the unit In HEAT mode the outdoor unit stops and the indoor unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 4 In DRY mode the indoor unit operates at low fan speed to adjust the room...

Page 7: ......

Page 8: ......

Reviews: