En-6

Earth 
(Ground) 
screw

Indoor unit terminal block

Disconnect switch

Please connect 

it to the specified 

terminal.

Outdoor unit or 

Branch box

•  To connect the indoor unit wires to the terminal correctly, refer to the 

fi

 gure for proper 

length. 

14AWG

Earth (Ground) wire

Conduit holder

Conduit connector

10-1/4 

(260)

10-5/8 
(270)

6.3. How to the install the indoor unit wire harness

(1) Remove the screws, then remove the conduit holder.
(2) Fasten the indoor unit wire harness to the conduit holder using the lock nut.
 

IMPORTANT: Refer to [6.1. Wiring system diagram] about the length of indoor unit wire 
harness.

(3) Use the screws to install the conduit holder provide with the indoor unit.
(4) Remove the screws, then remove the cable clamper.
(5) Connect indoor unit wire harness to the terminal.
 

Refer to the wiring diagram

(6) Use the screws to install the cable clamper.

Lock nut

Conduit holder

Conduit connector

6.4.  How to connect wiring to the terminals

Caution when wiring cable

When stripping off the insulation of a lead wire, always use a special tool such as a wire 
stripper. If there is no special tool available, carefully strip the insulation with a knife etc.
(1)  Use ring terminals with insulating sleeves as shown in the 

fi

 gure below to connect to 

the terminal block.

(2)  Securely clamp the ring terminals to the wires using an appropriate tool so that the 

wires do not come loose.

Strip : 3/8 in. (10 mm)

Ring terminal

Sleeve

(3) Use 

the 

speci

fi

 ed wires, connect them securely, and fasten them so that there is no 

stress placed on the terminals.

(4)  Use an appropriate screwdriver to tighten the terminal screws. Do not use a screw-

driver that is too small, otherwise, the screw heads may be damaged and prevent the 
screws from being properly tightened.

(5)  Do not tighten the terminal screws too much, otherwise, the screws may break.

Screw with special washer

Wire

Ring terminal

Terminal blocks

Wire

Screw with special washer

Ring terminal

(6)  See the table below for the terminal screw tightening torques.

Tightening torque [lbf·in (N·m)]

M4 screw

11 to 16 (1.2 to 1.8)

 CAUTION

•  Attach the cable clamp 

fi

 rmly by holding the connection cable, and make sure that the 

clamp is 

fi

 xed securely. 

Incomplete attachment of the cable clamp might cause a malfunction of the open 
panel.

•  Match the terminal block numbers and connection cable colors with those of the 

outdoor unit.

Erroneous wiring may cause burning of the electric parts.

•  Connect the connection cables 

fi

 rmly to the terminal block. Imperfect installation may 

cause a 

fi

 re.

•  Always fasten the outside covering of the connection cable with the cable clamp. 

(If the insulator is chafed, electric discharge may occur.)

•  Always connect the ground wire.
•  Do not use the earth screw of the indoor unit for the connection other than a speci

fi

 ed 

outdoor unit.

7. FINISHING 

 (1)  Insulate between pipes.

•  Insulate suction and discharge pipes separately.
•  For rear, right, and bottom piping, overlap the connection pipe heat insulation and 

indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap.

•  For left and left rear piping, butt the connection pipe heat insulation and indoor unit 

pipe heat insulation together and bind them with and vinyl tape so that there is no gap.

•  For left and left rear piping, wrap the area which accommodates the rear piping 

housing section with cloth tape.

•  For left and left rear piping, bind the connection cable to the top of the pipe with 

vinyl tape.

•  For left and left rear piping, bundle the piping and drain hose together by wrapping 

them with cloth tape over the range within which they 

fi

 t into the rear piping 

housing section.

 (2)  Temporarily fasten the connection cable along the connection pipe with vinyl tape. 

(Wrap to about 1/3 the width of the tape from the bottom of the pipe so that water 
does not enter.)

 (3)  Fasten the connection pipe to the outside wall with a saddle, etc.
 (4)  Fill the gap between the outside wall pipe hole and the pipe with sealer so that rain 

water and wind cannot blow in.

 (5)  Fasten the drain hose to the outside wall, etc.

*Locally purchased

Pipe

Saddle*

Outside wall cap*

Sealer putty*

(Outdoors)

Wall

Unit: in. (mm)

Screw

9320456016_IM.indb   6

9320456016_IM.indb   6

12/4/2014   2:20:59 PM

12/4/2014   2:20:59 PM

Summary of Contents for ASU12RLS3

Page 1: ... fingers When Installing In a Ceiling or Wall Make sure the ceiling wall is strong enough to hold the unit s weight It may be necessary to construct a strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause drip ping and water damage to walls and floors In an Area with High Winds Securely anchor the outdoor uni...

Page 2: ...ing with conventional refrigerant R22 and for safety Therefore check beforehand The charging port thread diameter for R410A is 1 2 20 UNF Be more careful that foreign matter oil water etc does not enter the piping than with refrigerant R22 models Also when storing the piping securely seal the opening by pinching taping etc When charging the refrigerant take into account the slight change in the co...

Page 3: ...r volatile inflammables such as paint thinner or gasoline If gas leaks and settles around the unit it can cause a fire Area where animals may urinate on the unit or ammonia may be generated Do not use the unit for special purposes such as storing food raising animals grow ing plants or preserving precision devices or art objects It can degrade the quality of the preserved or stored objects Do not ...

Page 4: ...t pipes top Rear piping Indoor unit drain hose bottom No gap Hexagonal wrench Drain cock Drain cap For left outlet piping cut off the piping outlet cutting groove with a hacksaw Indoor unit drain hose Drain cap Remove the drain cap by pull ing at the projection at the end of the cap with pliers etc Removal method of drain hose Remove the screw at the left of drain hose and pull out drain hose Inst...

Page 5: ...ut correctly Tighten the flare nuts with a torque wrench using the specified tightening method Otherwise the flare nuts could break after a prolonged period causing refrigerant to leak and generate hazardous gas if the refrigerant comes into contact with a flame CAUTION Connect the piping so that the control box cover can easily be removed for servicing when necessary In order to prevent water fro...

Page 6: ...erminal screw tightening torques Tightening torque lbf in N m M4 screw 11 to 16 1 2 to 1 8 CAUTION Attach the cable clamp firmly by holding the connection cable and make sure that the clamp is fixed securely Incomplete attachment of the cable clamp might cause a malfunction of the open panel Match the terminal block numbers and connection cable colors with those of the outdoor unit Erroneous wirin...

Page 7: ...roller holder Tapping screw small remote controller mounting Remote controller 2 Push 1 Set Overlap the insulation Vinyl tape Wrap with cloth tape Cloth tape Drain hose Connection cable Pipe Drain hose Drain hose Connection pipe Wall pipe Connection cable Left piping For connection from the left rear Pipe Connection pipe heat insulation Indoor unit pipe heat insulation Bind the pipes together so t...

Page 8: ...ng intake grille and front panel See 9 FRONT PANEL REMOVAL AND INSTALLATION and 9 1 Front panel removal 11 2 2 Removing control cover Screw 2 Control cover Control box Screw 1 Remove the screw 1 and 2 then remove the control cover 11 2 3 Installing relay control board and relay wire terminal Control unit board Connector CN2 Relay wire Notice 2 Clasps Connector CND01 Relay control board Clasp 2 Not...

Page 9: ...es to the function settings used to control the indoor unit according to the installation conditions Incorrect settings can cause the indoor unit to malfunction After the power is turned on perform the FUNCTION SETTING according to the installation conditions using the remote controller The settings may be selected between the following two Function Number or Setting Value Settings will not be cha...

Page 10: ...the FUNCTION SETTING be sure to turn off the power and turn it on again 13 2 Temperature correction NOTE When changing Function 95 perform this setting before other Room temp control settings Function 30 31 92 93 If Function 95 is not set first Room temperature control settings Function 30 31 92 93 will be reset and you must re do them again Heat Insulation condition building insulation Heat insul...

Page 11: ...r to the operating manual 1 Stop the air conditioner operation 2 Press the MODE button and the FAN button simultaneously for 2 seconds or more to start the test run Test run display 3 Press the START STOP button to stop the test run 15 CUSTOMER GUIDANCE Explain the following to the customer in accordance with the operating manual 1 Starting and stopping method operation switching temperature adjus...

Page 12: ...rip detection 9 5 Compressor rotor position detection error 9 7 Outdoor unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator green TIMER i...

Reviews: