Care and Cleaning

 Replacing the air cleaning 

fi

 lter

1

  Remove the air 

fi

 lter. (Refer to step 1 in “Replacing the air 

fi

 lter”.)

2

  Release 2 latches 

a

 of the 

fi

 lter holder, and turn over the holder 

in direction of arrow 

b

.

Remove the soiled air cleaning 

fi

 lter 

c

.

Note:

 Air 

cleaning 

fi

 lter is attached on each air 

fi

 lter.

a

a

b

c

3

  Attach new or maintained air cleaning 

fi

 lter 

d

 to the 

fi

 lter holder.

New air cleaning 

fi

 lter can be attached to either of the right holder 

or the left holder.

d

4

  Latch 2 corners of the 

fi

 lter holder 

e

 to the air 

fi

 lter 

fi

 rmly.

e

e

5

  Reinstall the air 

fi

 lter. (Refer to step 6 in “Cleaning the air 

fi

 lter”.)

6

  Close the intake grille 

fi

 rmly.

(Refer to step 4 in “Cleaning the intake grille” on page 10.)

Following 2 types of air cleaning 

fi

 lters are used in this product.

When you replace them, purchase dedicated air cleaning 

fi

 lters for this 

product.

Apple-catechin 

fi

 lter: UTR-FA16

 

(1 sheet)

The Apple-catechin 

fi

 lter uses static electricity to clean 

fi

 ne particles 

and dust in the air such as tobacco smoke and plant pollen that are 
too small to see.

• This 

fi

 lter is disposable. Do not wash or reuse it.

•  Once you open the package, use it as soon as possible. The 

cleaning effect is reduced if the 

fi

 lter is left with the package opened.

• Replace the 

fi

 lter once every 3 months under normal use.

• By setting the fan speed high, the air cleaning effect increases.

Ion deodorization 

fi

 lter: UTR-FA16-2

 

(Light blue, 1 sheet)

The 

fi

 lter deodorizes by powerfully decomposing absorbed odors 

using the oxidizing and reducing effects of ions generated by the 
ultra-

fi

 ne-particle ceramic.

• To maintain the deodorizing effect, clean the 

fi

 lter once every 3 

months as follows:

1.

  Remove the 

fi

 lter.

2.

   Flush the 

fi

 lter with high-pressure hot water until the surface of 

the 

fi

 lter is covered with water.

3.

   Wash the 

fi

 lter gently with diluent neutral detergent. Do not wash 

it by wringing or rubbing to prevent reducing the deodorizing 
effect by damage.

4.

  Rinse the 

fi

 lter well with water 

fl

 ow.

5.

  Dry the 

fi

 lter throughly in a shaded place.

6.

  Reinstall the 

fi

 lter to the indoor unit.

• Replace the 

fi

 lter once every 3 years under normal use.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 
FAN operation for half a day to dry the internal parts throughly before 
you perform normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the product performance even if you have maintained the unit 
with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.

Filter Indicator Reset (Special setting)

•  This function can be used if set correctly during installation.

Please consult authorized service personnel in order to use this 
function. 

•  Clean the air 

fi

 lter when the indicator lamp show the following;

ECONOMY indicator lamp

Flashes 3 times, at intervals of 21 
seconds

After cleaning, reset the 

fi

 lter indicator by pushing the “MANUAL AUTO” 

button on the indoor unit for 3 seconds or less.

9333003283-02_OM_EN.indd   11

9333003283-02_OM_EN.indd   11

2017/11/29   10:24:12

2017/11/29   10:24:12

Summary of Contents for ASTG09KMCB

Page 1: ...leakage be sure to keep away from fire or any flammables and consult authorized service personnel If you see lightning or hear thunder there might be a lightning strike To prevent electric shock hazard turn off the air conditioner by using the remote controller and do not touch the unit or the power plug during thunderstorm The appliance shall be stored in a room without continuously operating ign...

Page 2: ...hose items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or c...

Page 3: ...rn to position 3 Keeping the position 4 7 during COOL or DRY mode may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 8 Drain h...

Page 4: ... is not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up th...

Page 5: ...use because it will cause incorrect operation During the test run the OPERATION indicator and the TIMER indicator blink simultaneously To quit the test run that is started unintentionally you need to turn off the air conditioner by pressing the START STOP button See page 2 18 CLOCK ADJUST button Used for adjusting the clock 19 SEND button Used for sending the timer clock setting See page 6 20 TIME...

Page 6: ...operation Note for timer settings Any interruption of the power supply such as a blackout or cutting off of a circuit breaker makes the set internal clock incorrect In such a case the TIMER indicator on the indoor unit blinks and you need to readjust the setting Timer Operation ON timer or OFF timer You can set the ON timer or OFF timer with the following steps 1 Press the TIMER SETTING button to ...

Page 7: ...nd OFF timer can be combined and up to 4 reservations program per day and 28 reservations per week Before setting the program please set the week and time of the air con ditioner first If the week and time are not set the weekly timer will not operate cor rectly at the set time Please refer to remote controller preparation page 2 Example of WEEKLY timer 1 No timer settings Program 9 00 OFF Program...

Page 8: ...n the room the set temperature will not be changed This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to th...

Page 9: ...ces Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat fro...

Page 10: ...he shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating n...

Page 11: ...g absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as follows 1 Remove the filter 2 Flush the filter with high pressure hot water until the surface of the filter is covered with water 3 Wash the filter gently with diluent neutral detergent Do not wash it by wringing o...

Page 12: ...to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Outdoor unit emits water During heating operation the outdoor un...

Reviews: