En-12
When you return to the “Monitor” screen, the icon is displayed.
To check the function, press the [Enter button] and select the
icon with the [Cursor button (Left/Right)].
Cool
Monitor
High
°C
24
Menu
Set temp. auto return: Remaining 30 minutes
Mo 10:00
End:
3-2-3. Set temp. range limitation setting
1
In “Function” screen, select [Set temp. range] with the
[Cursor button (Up/Down)].
Function
Air flow direction
Economy
Set temp. auto return
Set temp. range
Off
Disable
Timer
Mo 10:00
Disable
Setting:
Back:
To change the setting, press the [Enter button].
2
“Set temp. range” screen is displayed.
Set temp. range
Enable/Disable setting
Temp. setting
Cool/Dry
Heat
Auto
Lower
Upper
18
°C
30
°C
30
°C
30
°C
16
°C
18
°C
Disable
Mo 10:00
Setting:
Back:
Set temp. au...
Air flow dire...
Select the item with the [Cursor button (Up/Down)], and
press the [Enter button].
3
For [Enable/Disable setting], select [Enable] or [Disable]
with the [Cursor button (Up/Down)], and press the [Enter
button] to complete the setting.
Enable/Disable setting
Enable
Set temp. range
Temp. setting
Cool/Dry
Heat
Auto
Lower
Upper
18
°C
30
°C
30
°C
30
°C
16
°C
18
°C
Mo 10:00
OK:
Cancel:
Set temp. au...
Air flow dire...
3
For [Enable/Disable setting], select [Enable] or [Disable]
with the [Cursor button (Up/Down)], and press the [Enter
button] to complete the setting.
Set temp. auto return
Enable/Disable setting
Enable
Return time and temp. setting
Time
Temp.
/
//
Cool/Dry
26
°C
30min.
/
26
°C
30min.
Heat
Mo 10:00
OK:
Cancel:
Air flow dire...
Set temp. range
4
For [Return time and temp. setting], select operation
mode with the [Cursor button (Up/Down)], and press
the [Enter button]. Adjust the value with the [Cursor but-
ton (Up/Down)].
With the [Cursor button (Left/Right)], the cursor can be
switched [Time] and [Temp].
/
Set temp. auto return
Enable/Disable setting
Enable
Return time and temp. setting
Time
Temp.
Cool/Dry
26
°C
30min.
26
°C
30min.
Heat
Mo 10:00
Air flow dire...
Set temp. range
OK:
Cancel:
To complete the setting, press the [Enter button]. To re-
turn to the “Function” screen, press the [Cancel button].
Notes
• The set time can be set from 30 to 120 minutes in
units of 10 minutes.
• Possible temperature setting ranges in the operation
mode are as follows:
Cool, Dry ..........................
18 to 30 °C (64 to 88 °F)
Heat ..................................
16 to 30 °C (60 to 88 °F)
• If any ranges have been set in [Set temp. range]
setting, adjustable temperature range in this setting
follows the restricted range.
• If you set any ranges in the [Set temp. range] setting
after setting of [Set temp. auto return], the restricted
range set in the [Set temp. range] also overrides [Set
temp. auto return] setting.
• Even if the temperature setting change is done on
the secondary remote controller, it returns to the set
value in [Set temp. auto return] on the primary remote
controller.