![Fujitsu AOYG18LBCA Technical Manual Download Page 56](http://html.mh-extra.com/html/fujitsu/aoyg18lbca/aoyg18lbca_technical-manual_2344273056.webp)
- 50 -
DUC
T TYPE
ARYG18-5
4LHT
B
P
Input signal type
• Indoor unit
Input signal type is only "Edge".
• External input and output PCB
The input signal type can be selected.
Signal type (edge or pulse) can be switched by the DIP switch 2 (SW2) on the External input and
output PCB.
Edge
Edge
Pulse
The width of pulse must be longer than 200 msec.