Self-diagnosis function table (Flashing LED Display)
Applicable model : ASY9LSACW, ASY12LSACW
* Detailed Trouble Display (secondary level) can be indicated by pressing Test Operation button.
Error
Operation
Timer
Error
Operation
Timer
Serial Signal
Normal
1 sec
Serial reverse signal error
0.1sec
0.5sec
Normal Serial Reverse Signal can not be
Error
blinking at operation start up
blinking
2 times
received more than 10 seconds
>>Releases when it becomes normal
Signal reverse signal error
0.1sec
0.5sec
Normal Serial Reverse Signal can not be
during operation
blinking
3 times
received more than 7 sec (after receiving
effective reverse transfer signal)
>>Releases when it becomes normal
Serial forward signal error
0.1sec
0.5 sec
Normal Serial Forward Signal can not be
at operation start up
blinking
4 times
received more than 10 sec
>>Releases when it becomes normal
Serial forward signal error
0.1sec
0.5sec
Normal Serial Forward Signal can not be
during operation
blinking
5 times
received more than 10 sec ( after receiving
effective forward transfer signal)
>>Releases when it becomes normal
Indoor unit
0.5sec
0.1sec Indoor Temperature
0.1sec
0.5sec
Thermister detection value is open when
Thermister
2 times
blinking Thermister Open
blinking
2 times
AC plug is inserted
error
>>Releases when value becomes normal
Pipe Thermister
0.1sec
0.5sec
Thermister detection value is open or short
Open or Short
blinking
3 times
when AC plug is inserted
>>Releases when value becomes normal
Outdoor unit
0.5sec
0.1sec Discharge Thermister
0.1sec
0.5sec
Thermistor detection value is open or short
Thermister
3 times
blinking Open or Short
blinking
2 times
error
>>Outdoor unit stops
Releases when it becomes normal
Heat Exchanger
0.1sec
0.5sec
Thermistor detection value is open
Thermister Open
blinking
3 times
>>Outdoor unit stops
Releases when it becomes normal
Outdoor Temperature
0.1sec
0.5sec
Thermistor detection value is open or short
Thermistor Open or Short
blinking
4 times
>>Outdoor unit stops
Releases when it becomes normal
Indoor unit
0.5sec
0.1sec Forced Automatic SW
0.1sec
0.5sec
Forced Auto SW is ON for more than
control error
4 times
blinking welded
blinking
2 times
10 seconds continuously
>>Error is indicated while it is ON
Normal Operation other than error indition
Main Relay welded
0.1sec
0.5sec
Serial Reverse Signal is received 1 min.
blinking
3 times
after Main relay becomes OFF
>>Error is indicated while serial reverse
signal is input on normal operation
Normal operation except error indication
Power interruption error
0.1sec
0.5sec
50/60Hz is not detected after 2 seconds of
blinking
4 times
power ON.
>>Error is indicated and unit is stopped