background image

En-13

TROUBLESHOOTING

Symptom

Doesn’t operate at all:

Poor Cooling performance:

The unit operates
differently from the Remote
Control Unit’s setting:

See Page

7 - 8

5

4

CHECK ONCE

MORE

Items to check

Is the Power Supply Plug disconnected its outlet?

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the timer operating?

Is the air filter dirty?

Air the air conditioner’s intake grille or outlet port blocked?

Did you adjust the room temperature settings (thermostat) cor-
rectly?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)

In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?

Is the unit set for SUPER QUIET operation?

Are the Remote Control Unit’s batteries dead?

Are the Remote Control Unit’s batteries loaded properly?

OPERATING TIPS

If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator Lamp (Fig. 3 

6

)

flashes, immediately stop operation, disconnect the Power Supply Plug (Fig. 1 

C

), and consult authorized service personnel.

The air conditioner power has been interrupted by a power
failure. The air conditioner will then restart automatically
in its previous mode when the power is restored.

Operated by setting before the power failure.

If a power failure occurs during TIMER operation, the timer
will be reset and the unit will begin (or stop) operation at the
new time setting. In the event that this (kind of timer fault
occurs the TIMER Indicator Lamp will flash (see Page. 3).

Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
disconnect the Power Supply Plug, reconnect it, and then
use the Remote Control Unit to resume operation.

AUTO Restart

In Event of Power Interruption

Summary of Contents for AOY12ASQT

Page 1: ...UAL MANUAL DE FUNCIONAMIENTO P N9313483029 01 Indoor Unit ASY9ASSCW ASY9ASSTW ASY12ASQTW Outdoor Unit AOY9AGSC AOY9AGST AOY12ASQT COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Refer to the fold out page on the cover FUJITSU GENERAL LIMITED English Español ...

Page 2: ...UAL MANUAL DE FUNCIONAMIENTO P N9313483029 01 Indoor Unit ASY9ASSCW ASY9ASSTW ASY12ASQTW Outdoor Unit AOY9AGSC AOY9AGST AOY12ASQT COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Refer to the fold out page on the cover FUJITSU GENERAL LIMITED English Español ...

Page 3: ...ay from either the in door or outdoor units Avoid installing the air conditioner near a fireplace or other heating apparatus When installing the indoor and outdoor unit take precautions to prevent access to infants Do not use inflammable gases near the air conditioner DANGER CAUTION En 1 This figure shows the control display when all indicator lamps are on It may differ from the actual display Fig...

Page 4: ...ay from either the in door or outdoor units Avoid installing the air conditioner near a fireplace or other heating apparatus When installing the indoor and outdoor unit take precautions to prevent access to infants Do not use inflammable gases near the air conditioner DANGER CAUTION En 1 This figure shows the control display when all indicator lamps are on It may differ from the actual display Fig...

Page 5: ...onditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER QUIE...

Page 6: ...EL TIMER button Q FAN CONTROL button R START STOP button S AIR FLOW DIRECTION button T SWING LOUVER button U ACL button V TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration the unit will switch to test...

Page 7: ...mote control unit s operating range becomes appre ciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid on the re v...

Page 8: ...er the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Cooling As ...

Page 9: ...on is pressed to recommence operation within two hours after stopping automatic operation the unit will begin op erating from the same mode as before Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from ti...

Page 10: ...e time while the ON TIMER mark on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 O to select ON TIMER opera tion The ON Timer mark will be shown on the remote control unit s dis play The Indoor Unit Timer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANCEL TIMER bu...

Page 11: ...button To Stop the Air Conditioner During Timer Operation Press the START STOP button About the SLEEP timer To prevent excessive cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accord ance with the time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat set...

Page 12: ...the louvers are operated outside the range 1 3 for more than 30 minutes they will be automatically returned to the 3 range When used in a room with infants chil dren elderly or sick persons the air di rection and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 S Each time the button is pressed the air ...

Page 13: ...ntrol Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop operation press the MANUAL AUTO button once again Controls are located inside the Intake Grille When the air conditioner is operated with the controls on the Main Unit it will operate under the same mode as the AUTO mode selected on the Re mote C...

Page 14: ...aning and care For more information consult authorized service personnel When cleaning the unit s body do not use water hotter than 40 C harsh abrasive cleansers or volatile agents like benzene or thinner Do not expose the unit body to liquid insecticides or hairsprays When shutting down the unit for one month or more first allow the fan mode to operate continuously for about one half day to allow...

Page 15: ...ntraction of the front cover due to temperature changes Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner If the unit is stopped and then immediately started again the com pressor will not operate for about 3 minutes in order to prevent fuse blowouts Whenever the Power Supply Plug is disconnec...

Page 16: ...emote Control Unit s batteries loaded properly OPERATING TIPS If the problem persists after performing these checks or if you notice burning smells or the TIMER indicator Lamp Fig 3 6 flashes immediately stop operation disconnect the Power Supply Plug Fig 1 C and consult authorized service personnel The air conditioner power has been interrupted by a power failure The air conditioner will then res...

Page 17: ...circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions con...

Page 18: ......

Page 19: ...ay from either the in door or outdoor units Avoid installing the air conditioner near a fireplace or other heating apparatus When installing the indoor and outdoor unit take precautions to prevent access to infants Do not use inflammable gases near the air conditioner DANGER CAUTION En 1 This figure shows the control display when all indicator lamps are on It may differ from the actual display Fig...

Page 20: ...UAL MANUAL DE FUNCIONAMIENTO P N9313483029 01 Indoor Unit ASY9ASSCW ASY9ASSTW ASY12ASQTW Outdoor Unit AOY9AGSC AOY9AGST AOY12ASQT COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Refer to the fold out page on the cover FUJITSU GENERAL LIMITED English Español ...

Reviews: