Trouble shooting 6
INDOOR UNIT Error Method:
Detective Actuators:
Detective details:
Forecast of Cause :
62.9
103.3
134.2
176.0
233.2
312.3
Resistance Value (k )
Temperature (°F)
OK
OK
OK
17.1
25.6
39.6
Resistance Value (k )
Temperature (°F)
Indoor Heat Ex.(Pipe)
Thermistor Error
Indoor unit Controller PCB
Heat Ex. temperature thermistor
When Heat Ex. Temperature Thermistor open or short-circuit is detected.
1. Connector connection failure 2.Thermistor failure 3. Controller PCB failure
Check Point 1 : Check connection of Connector
Check if connector is removed.
Check erroneous connection.
Check if thermistor cable is open.
>>Upon correcting the removed connector or miss-wiring, reset the power.
Check Point 2 : Remove connector and check Thermistor resistance value
Thermistor Characteristics (Approx. value)
If Thermistor is either open or shorted, replace it and reset the power.
Check Point 3 : Check voltage of Controller PCB (DC5.0V)
Make sure circuit diagram of indoor unit and check terminal voltage at Thermistor (DC5.0V)
If the voltage does not appear, replace Controller PCB.
68°F
50°F
41°F
32°F
23°F
14°F
122°F
11.6
140°F
10.4
149°F
104°F
86°F
Indicate or Display:
THERMISTOR
(ROOM TEMP.)
THERMISTOR
(PIPE TEMP.)
BLACK
CN3
1
2
1
2
1
2
1
2
BLACK
BLACK
BLACK
02-09
Outdoor Unit : No indication
Indoor Unit : Operation lamp: 4 time Flash, Timer lamp: 2 time Flash
Economy lamp: Continuous flash.
ERROR CODE : [E : 42]
WHITE
RED
1
2
3
1
2
3
CN1
Summary of Contents for AOU18RLB
Page 3: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 24: ...2 TROUBLE SHOOTING R410A WALL MOUNTED type INVERTER ...
Page 63: ...3 APPENDING DATA R410A WALL MOUNTED type INVERTER ...
Page 71: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan December 2014 Printed in Japan ...