8. COMPRESSOR CONTROL
1. OPERATION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the Table 10 .
Cooling
Heating
Minimum
Maximum
Minimum
Maximum
AOU18RLB
AOU24RLB
12rps
12rps
104rps
12rps
12rps
119rps
104rps
AOU18RLB
AOU24RLB
AOU18RLB
AOU24RLB
( Table 10 : Compressor frequency range )
2. OPERATION FREQUENCY CONTROL AT NORMAL START UP
The compressor frequency soon after the start-up is controlled as shown in the Fig. 11 .
( Fig. 11 : Compressor control at start-up )
Time
Time
Time
Time
Time
(Frequency)
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Time
Time
Time
Time
Time
(Time)
Frequency
Time
6
Frequency
Time
6
40rps
59rps
72rps
80rps
101rps
110rps
80sec
110sec
140sec
200sec
410sec
350sec
3. LIMITATION OF COMPRESSOR FREQUENCY BY OUTDOOR TEMPERATURE
The minimum compressor frequency is limited by outdoor temperature as shown in the Table 11 .
( Table 11 : Limitation of compressor frequency )
AOU24RLB
Under
Over
Under
Over
Under
Over
24rps
18rps
16rps
12rps
32°F (0°C)
50°F (10°C)
104°F (40°C)
[ Cooling/ Dry ]
[ Heating ]
AOU18RLB
AOU18RLB
Under
Ove
Under
Over
r
Under
Over
Under
Over
24rps
24rps
18rps
16rps
12rps
32°F (0°C)
50°F (10°C)
104°F (40°C)
Under
Over
Under
Over
18rps
16rps
16rps
45°F (7°C)
37°F (3°C)
104°F (40°C)
AOU24RLB
Under
Over
24rps
Under
Over
Under
Over
18rps
16rps
16rps
45°F (7°C)
37°F (3°C)
104°F (40°C)
[ Cooling/ Dry ]
[ Heating ]
01-08
119rps
Dry
Minimum
Maximum
16rps
16rps
30rps
38rps
Summary of Contents for AOU18RLB
Page 3: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 24: ...2 TROUBLE SHOOTING R410A WALL MOUNTED type INVERTER ...
Page 63: ...3 APPENDING DATA R410A WALL MOUNTED type INVERTER ...
Page 71: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan December 2014 Printed in Japan ...