background image

En-2

FEATURES AND FUNCTIONS

INVERTER

At the start of operation, a large power is used to bring the
room quickly to the desired temperature. Afterwards, the
unit automatically switches to a low power setting for eco-
nomic and comfortable operation.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY but-
ton on the Remote Control Unit so as to avoid going moldy
and restrain the breed of bacterium.

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched au-
tomatically to maintain the set temperature, and the tem-
perature is kept constant at all times.

PROGRAM TIMER

The program timer allows you to integrate OFF timer and
ON timer operations in a single sequence. The sequence
can involve one transition from OFF timer to ON timer, or
from ON timer to OFF timer, within a twenty-four hour pe-
riod.

SLEEP TIMER

When the SLEEP button is pressed during Heating mode,
the air conditioner’s thermostat setting is gradually lowered
during the period of operation; during cooling mode, the
thermostat setting is gradually raised during the period of
operation. When the set time is reached, the unit automati-
cally turns off.

WIRELESS REMOTE CONTROL UNIT

The Wireless Remote Control Unit allows convenient con-
trol of air conditioner operation.

SWING OPERATION

The Air Flow Direction Louvers swings automatically up and
down so that the air speeds to every nook and corner of
your room.

REMOVABLE OPEN PANEL

The indoor unit’s Open Panel can be removed for easy clean-
ing and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.

SUPER QUIET OPERATION

When the FAN CONTROL button is used to select QUIET,
the unit begins super-quiet operation; the indoor unit’s air-
flow is reduced to produce quieter operation.

POLYPHENOL CATECHIN AIR CLEANING FILTER

The polyphenol catechin air cleaning filter uses static elec-
tricity to clean the air of fine particles and dust such as to-
bacco smoke and plant pollen that are too small to see.
The filter contains catechin, which is highly effective against
various bacteria by suppressing the growth of the bacteria
adsorbed by the filter.
Note that when the air cleaning filter is installed, the amount
of air produced decreases, causing a slight decrease in the
air conditioner's performance.

NEGATIVE AIR IONS DEODORIZING FILTER

It comprises pottery super micro particles, which can pro-
duce negative air ions having the effect of deodorizing and
can absorb and remit the peculiar smell at home.

WIRED REMOTE CONTROL UNIT (OPTION)

The optional wired remote control unit (model No.: UTB-UUB) can be used.
When you use remote control unit, there are following different points as compared with using wireless remote control unit.

[The additional functions for wired ones]
    • Weekly timer
    • Temperature set back timer

[The restricted functions for wired ones]
    • QUIET can't be selected in FAN MODE.
    • Sleep-timer can't be used.

And you can't use both wired remote control unit and wireless simultaneously.
(Only one kind can be selected)

05L256_9315255013-01_En

12/12/05, 3:32 PM

2

Summary of Contents for AOU18RL

Page 1: ...LIMITED P N9315255013 01 OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO English Français Español Indoor Unit ASU18RL Outdoor Unit AOU18RL HEAT COOLING MODEL REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE 05L256_9315255013 01_Cover 2005 12 6 9 12 AM 1 ...

Page 2: ... plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Connection valves become hot during Heating handle with care Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille an...

Page 3: ... Open Panel can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER QUIET OPERATION When the FAN CONTROL button is used to select QUIET the unit begins super quiet operation the indoor unit s air flow is reduced to produce quieter operation POLYPHENOL CATECHIN AIR CLEANING FILT...

Page 4: ... Unit G Drain port bottom H Intake Port I Outlet Port Fig 6 Remote Control Unit J SLEEP button K MASTER CONTROL button L SET TEMP button M COIL DRY button N Signal Transmitter O TIMER MODE button P TIMER SET button Q FAN CONTROL button R START STOP button S SET button T SWING button U RESET button V TEST RUN button This button is used when installing the conditioner and should not be used un der n...

Page 5: ... line connection turn on the cir cuit breaker Load Batteries AAA R03 LR03 2 1 Press and slide the battery compartment lid on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 W Use the tip of a bal...

Page 6: ...utton Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature ap...

Page 7: ...ow fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time Dur...

Page 8: ... display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the...

Page 9: ... the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty min...

Page 10: ...r more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Fig 6 S Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow...

Page 11: ...ess the COIL DRY button again during COIL DRY Operation COIL DRY Opera tion can be reset The COIL DRY Operation cannot get rid of the existed mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure To select SWING Operation Press the SWING button Fig 6 T The SWING Display Fig 7 c will light In this mode the Air Flow Direction Lo...

Page 12: ... air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash the fi...

Page 13: ... In regard to the Air Cleaning Filters POLYPHENOL CATECHIN AIR CLEANING FILTER one sheet The Air Cleaning Filters are disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be excha...

Page 14: ...ensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit...

Page 15: ...ce is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating mode under...

Page 16: ...xchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 80 or more Tips for saving ene...

Page 17: ...05L256_9315255013 01_En 2005 12 9 11 49 AM 16 ...