Air Cleaning Filter Installation

1. Open the Intake Grille and remove the Air

filters.

2. Install the Air cleaning filter set (set of 2).

1

Set the air cleaning filter into the air cleaning filter
frame.

2

Engage the latch at both ends of the filter with the
two hooks at the rear of the air cleaning filter frame.

Take care that the air cleaning filter does not project be-
yond the frame.

3

Engage the four fixing locations at the top and bot-
tom of the air cleaning filter frame with the hooks of
the air filter.

3. Install the two Air filters and close the

Intake Grille.

When air cleaning filters are used, the effect will increased
by setting the fan speed to “High”.

Air cleaning filter set

Air cleaning filter frame

Air cleaning filter

Hook (2 places at the rear)

Latch (2 places)

Fixing location, hook (4 places)

Replacing dirty Air cleaning filters

Replace filters with the following components (purchased
separately).

POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA03-2

Negative air ions deodorizing filter: UTR-FA03-3

1. Open the Intake Grille and remove the Air

filters.

2. Replace them by two new Air cleaning

filters.

1

Remove the old air cleaning filters in reverse order of
their installation.

2

Install in the same way as for installation of the air
cleaning filter set.

3. Install the two Air filters and close the

Intake Grille.

In regard to the Air Cleaning Filters

POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)

The Air Cleaning Filters are disposable filters. (They can
not be washed and reused.)

For storage of the Air Cleaning Filters, use the filters as
soon as possible after the package has been opened.
(The air cleaning effect decreases when the filters are left
in the opened package)

Generally, the filters should be exchanged about every
three months.

Please buy delicated air cleaning filters (UTR-FA03-2) (Sold
separately) to exchange the used dirty air cleaning filters.

[Negative air ions deodorizing filter (one sheet) — light blue]

The filters should be exchanged about every three years
so as to maintain the deodorizing effect.

Filter frame is not a one-off product.

Please buy delicated deodorizing filter (UTR-FA03-3) (Sold
separately) when exchanging the filters.

Maintenance of Deodorizing Filters

In order to maintain the deodorizing effect, please clean the
filter in the follow way once three months.

1

Remove the deodorizing filter.

2

Clean with water and dry in the air.
1) Flush the filters with high-pressure hot water until

the surface of the filters are covered with water.
Please flush with diluent neutral detergent.
Never wash by reaming or rubbing, otherwise it
will damage the deodorizing effect.

2) Rinse with water flow.
3) Dry in shade.

3

Reinstall the deodorizing filter.

CLEANING AND CARE

Air Filter

(Right & Left)

Air Filter

(Right & Left)

Air Filter(Right & Left)

Air Filter

(Right & Left)

Rear of the filter

05L256_9315255013-01_En

2005.12.9, 11:49 AM

12

Summary of Contents for AOU18RL

Page 1: ...LIMITED P N9315255013 01 OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO English Français Español Indoor Unit ASU18RL Outdoor Unit AOU18RL HEAT COOLING MODEL REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE 05L256_9315255013 01_Cover 2005 12 6 9 12 AM 1 ...

Page 2: ... plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Connection valves become hot during Heating handle with care Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille an...

Page 3: ... Open Panel can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER QUIET OPERATION When the FAN CONTROL button is used to select QUIET the unit begins super quiet operation the indoor unit s air flow is reduced to produce quieter operation POLYPHENOL CATECHIN AIR CLEANING FILT...

Page 4: ... Unit G Drain port bottom H Intake Port I Outlet Port Fig 6 Remote Control Unit J SLEEP button K MASTER CONTROL button L SET TEMP button M COIL DRY button N Signal Transmitter O TIMER MODE button P TIMER SET button Q FAN CONTROL button R START STOP button S SET button T SWING button U RESET button V TEST RUN button This button is used when installing the conditioner and should not be used un der n...

Page 5: ... line connection turn on the cir cuit breaker Load Batteries AAA R03 LR03 2 1 Press and slide the battery compartment lid on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 W Use the tip of a bal...

Page 6: ...utton Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature ap...

Page 7: ...ow fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time Dur...

Page 8: ... display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the...

Page 9: ... the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty min...

Page 10: ...r more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Fig 6 S Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow...

Page 11: ...ess the COIL DRY button again during COIL DRY Operation COIL DRY Opera tion can be reset The COIL DRY Operation cannot get rid of the existed mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure To select SWING Operation Press the SWING button Fig 6 T The SWING Display Fig 7 c will light In this mode the Air Flow Direction Lo...

Page 12: ... air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash the fi...

Page 13: ... In regard to the Air Cleaning Filters POLYPHENOL CATECHIN AIR CLEANING FILTER one sheet The Air Cleaning Filters are disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be excha...

Page 14: ...ensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit...

Page 15: ...ce is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating mode under...

Page 16: ...xchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 80 or more Tips for saving ene...

Page 17: ...05L256_9315255013 01_En 2005 12 9 11 49 AM 16 ...

Reviews: