![Fujitsu AOU 9RLFW Design & Technical Manual Download Page 48](http://html.mh-extra.com/html/fujitsu/aou-9rlfw/aou-9rlfw_design-and-technical-manual_2344097048.webp)
- (02 - 14) -
OU
TDOOR
UNIT
AO
U
9
-1
5
R
L
OU
TDOOR
UNIT
AO
U
9
-1
5
R
L
ADDITIONAL CHARGE CALCULATION
6.
MODEL
: AOU9RLFW
REFRIGERANT CHARGE
z
MODEL
: AOU12RLFW
REFRIGERANT CHARGE
z
MODEL
: AOU15RLS
REFRIGERANT CHARGE
z
Refrigerant type
R410A
Refrigerant amount
lb. oz.
1lb.14oz.
g
850
Pipe length
ft.
~49
66
0.22oz./ft.
(20g/m)
m
~15
20
Additional charge
oz.
0(chargeless)
3.5oz.
g
0(chargeless)
+100
Refrigerant type
R410A
Refrigerant amount
lb. oz.
2lb.5oz.
g
1050
Pipe length
ft.
~49
66
0.22oz./ft.
(20g/m)
m
~15
20
Additional charge
oz.
0(chargeless)
3.5oz.
g
0(chargeless)
+100
Refrigerant type
R410A
Refrigerant amount
lb. oz.
2lb.10.3oz.
g
1200
Pipe length
ft.
~49
66
0.22oz./ft.
(20g/m)
m
~15
20
Additional charge
oz.
0(chargeless)
3.5oz.
g
0(chargeless)
+100
Summary of Contents for AOU 9RLFW
Page 2: ...1 INDOOR UNIT WALL MOUNTED TYPE ASU9RLF ASU12RLF ASU15RLS DTR_AS044E_01 2010 08 09 ...
Page 33: ...2 OUTDOOR UNIT SINGLE TYPE AOU9RLFW AOU12RLFW AOU15RLS DTR_AO066E_01 2010 08 09 ...
Page 42: ... 02 08 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL WIRING DIAGRAMS 4 MODEL AOU9RLFW ...
Page 43: ... 02 09 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL MODEL AOU12RLFW ...
Page 44: ... 02 10 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL MODEL AOU15RLS ...
Page 53: ... 02 19 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL SOUND LEVEL CHECK POINT 8 2 39 3 8 in 1m ...