CAPACITY COMPENSATION RATE FOR PIPE LENGTH
5.
AND HEIGHT DIFFERENCE
MODEL
: AOU9RLFW
Height difference H
¿
1 Indoor unit is upper than outdoor unit.
¿
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
COOLING
Pipe length
5m
7.5m
10m
15m
20m
16ft.
25ft.
33ft.
49ft.
66ft.
Height
difference H
¼
1
Indoor unit is upper
than outdoor unit.
15m
49ft.
-
-
-
0.872
0.910
10m
33ft.
-
-
0.961
0.886
0.925
7.5m
25ft.
-
0.979
0.965
0.890
0.929
5m
16ft.
0.992
0.983
0.969
0.893
0.933
0m
0ft.
1.000
0.991
0.976
0.901
0.940
¼
2
Indoor unit is under
than outdoor unit
-5m
-16ft.
1.000
0.991
0.976
0.901
0.940
-7.5m
-25ft.
-
0.991
0.976
0.901
0.940
-10m
-33ft.
-
-
0.976
0.901
0.940
-15m
-49ft.
-
-
-
0.901
0.940
HEATING
Pipe length
5m
7.5m
10m
15m
20m
16ft.
25ft.
33ft.
49ft.
66ft.
Height
difference H
¼
1
Indoor unit is upper
than outdoor unit.
15m
49ft.
-
-
-
0.832
0.822
10m
33ft.
-
-
0.917
0.832
0.822
7.5m
25ft.
-
0.961
0.917
0.832
0.822
5m
16ft.
1.000
0.961
0.917
0.832
0.822
0m
0ft.
1.000
0.961
0.917
0.832
0.822
¼
2
Indoor unit is under
than outdoor unit
-5m
-16ft.
0.995
0.956
0.912
0.828
0.818
-7.5m
-25ft.
-
0.954
0.910
0.826
0.816
-10m
-33ft.
-
-
0.908
0.824
0.814
-15m
-49ft.
-
-
-
0.815
0.805
H
H
Summary of Contents for AOU 9RLFW
Page 2: ...1 INDOOR UNIT WALL MOUNTED TYPE ASU9RLF ASU12RLF ASU15RLS DTR_AS044E_01 2010 08 09 ...
Page 33: ...2 OUTDOOR UNIT SINGLE TYPE AOU9RLFW AOU12RLFW AOU15RLS DTR_AO066E_01 2010 08 09 ...
Page 42: ... 02 08 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL WIRING DIAGRAMS 4 MODEL AOU9RLFW ...
Page 43: ... 02 09 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL MODEL AOU12RLFW ...
Page 44: ... 02 10 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL MODEL AOU15RLS ...
Page 53: ... 02 19 OUTDOOR UNIT AOU9 15RL OUTDOOR UNIT AOU9 15RL SOUND LEVEL CHECK POINT 8 2 39 3 8 in 1m ...