- (02 - 01) -
O
U
TD
O
O
R U
N
IT
AO
G
07
-1
2L
LC
C
O
U
TD
O
O
R U
N
IT
AO
G
07
-1
2L
LC
C
SPECIFICATIONS
1.
NOTES:
●
Specifications are based on the following conditions.
Cooling: Indoor temperature of 27 °CDB / 19 °CWB and outdoor temperature of 35 °CDB / 24 °CWB.
Heating: Indoor temperature of 20 °CDB / 15 °CWB and outdoor temperature of 7 °CDB / 6 °CWB.
Pipe length: 5 m, Height difference: 0 m. (Outdoor unit - Indoor unit)
●
The protective function might work when using it out the operation range.
Type
INVERTER COOLING & HEATING
Model name
AO
Û
G07LLCC
AO
Û
G09LLCC
AO
Û
G12LLCC
Power source
230 V~ 50 Hz
Available voltage range
198-264 V
Starting current
A
3.0
3.5
5.4
Fan
Air flow rate
Cooling
m
3
/h
1,670
1,830
Heating
1,470
1,600
Type × Q'ty
Propeller fan × 1
Motor output
W
23
Sound pressure level
Cooling
dB (A)
47
50
Heating
48
51
Sound power level
Cooling
dB (A)
61
65
Heating
61
65
Heat exchanger type
Dimensions (H × W × D)
mm
650 × 504 × 18.2
642 × 504 × 18.2
612 × 504 × 18.2
Fin pitch
1.3
1.4
Rows × Stages
1 × 24
2 × 24
Pipe type
Copper
Fin type
Aluminium
Compressor
Type × Q'ty
Rotary × 1
Motor output
W
610
670
Refrigerant
Type (Global Warming Potential)
R410A (1975)
Charge
g
650
850
Refrigerant oil
Type
POE (VG74)
Enclosure
Material
Steel
Colour
BEIGE
(Approximate colour of MUNSELL 10YR 7.5/1.0)
Dimensions
(H × W × D)
Net
mm
535 × 663 × 293
Gross
595 × 790 × 395
Weight
Net
kg
24
26
Gross
27
29
Connection pipe
Size
Liquid
mm
Ø 6.35 (Ø 1/4 in.)
Gas
Ø 9.52 (Ø 3/8 in.)
Method
Flare
Pre-charge length
m
15
Max. length
20
Max. height difference
15
Operation range
Cooling
°C
-10 to 43
Heating
-15 to 24