- (02 - 06) -
O
U
TD
O
O
R U
N
IT
AO
G
07
-1
2L
LC
C
O
U
TD
O
O
R U
N
IT
AO
G
07
-1
2L
LC
C
MODEL
: AO
G12LLCC
H
H
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
COOLING
Pipe length (m)
5
7.5
10
15
20
Height difference H
(m)
Û
1
Indoor unit is higher
than outdoor unit.
15
-
-
-
0.858
0.868
10
-
-
0.929
0.872
0.882
7.5
-
0.960
0.933
0.876
0.885
5
0.992
0.964
0.937
0.879
0.889
0
1.000
0.972
0.944
0.887
0.896
Û
2
Indoor unit is lower
than outdoor unit.
-5
1.000
0.972
0.944
0.887
0.896
-7.5
-
0.972
0.944
0.887
0.896
-10
-
-
0.944
0.887
0.896
-15
-
-
-
0.887
0.896
HEATING
Pipe length (m)
5
7.5
10
15
20
Height difference H
(m)
Û
1
Indoor unit is higher
than outdoor unit.
15
-
-
-
0.896
0.879
10
-
-
0.968
0.890
0.879
7.5
-
0.994
0.968
0.896
0.879
5
1.000
0.994
0.968
0.896
0.879
0
1.000
0.994
0.968
0.896
0.879
Û
2
Indoor unit is lower
than outdoor unit.
-5
0.995
0.989
0.963
0.891
0.875
-7.5
-
0.987
0.961
0.889
0.873
-10
-
-
0.959
0.887
0.871
-15
-
-
-
0.878
0.862