- (02 - 09) -
O
U
TD
O
O
R U
N
IT
AO
G
45
-5
4L
ET
L
O
U
TD
O
O
R U
N
IT
AO
G
45
-5
4L
ET
L
CAPACITY COMPENSATION RATE FOR PIPE LENGTH
7.
AND HEIGHT DIFFERENCE
MODEL: AO
G45LETL
Height difference H
H
H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Outdoor unit
Outdoor unit
Connection pipe
Indoor unit
Indoor unit
Connection pipe
HEATING
Pipe length (m)
5
7.5
10
20
30
40
50
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
30
-
-
-
-
0.978
0.968
0.958
20
-
-
-
0.988
0.978
0.968
0.958
10
-
-
0.998
0.988
0.978
0.968
0.958
7.5
-
1.000
0.998
0.988
0.978
0.968
0.958
5
1.000
1.000
0.998
0.988
0.978
0.968
0.958
0
1.000
1.000
0.998
0.988
0.978
0.968
0.958
Û
2
Indoor unit is
lower than
outdoor unit.
-5
0.998
0.995
0.993
0.983
0.973
0.963
0.953
-7.5
-
0.993
0.991
0.981
0.971
0.961
0.951
-10
-
-
0.988
0.978
0.968
0.958
0.948
-20
-
-
-
0.968
0.958
0.949
0.939
-30
-
-
-
-
0.949
0.939
0.929
COOLING
Pipe length (m)
5
7.5
10
20
30
40
50
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
30
-
-
-
-
0.879
0.846
0.814
20
-
-
-
0.926
0.893
0.861
0.828
10
-
-
0.975
0.942
0.908
0.875
0.841
7.5
-
0.988
0.979
0.946
0.912
0.878
0.845
5
0.992
0.992
0.983
0.949
0.916
0.882
0.848
0
1.000
1.000
0.991
0.957
0.923
0.889
0.855
Û
2
Indoor unit is
lower than
outdoor unit.
-5
1.000
1.000
0.991
0.957
0.923
0.889
0.855
-7.5
-
1.000
0.991
0.957
0.923
0.889
0.855
-10
-
-
0.991
0.957
0.923
0.889
0.855
-20
-
-
-
0.957
0.923
0.889
0.855
-30
-
-
-
-
0.923
0.889
0.855