10) Room temperature control switching
This setting is used to set the room temperature control method when the wired remote controller is selected by the Indoor Room
Temperature Sensor Switching Function.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Control by the sensors
of both the indoor unit
and the wired remote
controller.
48
00
Control only by the sensor
of the wired remote
controller
01
11) Indoor unit fan control for energy saving (Only cooling mode)
Enable or disable indoor unit fan control when the outdoor unit is stopped.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
No
49
00
Yes
01
* If setting value is “00”:
When the outdoor unit is stopped, the indoor unit fan operates following the setting on the remote controller continuously.
* If setting value is “01”:
When the outdoor unit is stopped, the indoor unit fan operates at very low speed intermittently.
Summary of Contents for AO*G30LETL series
Page 2: ...1 INDOOR UNIT DTR_AR064E_01 2013 02 28 DUCT TYPE AR G30LMLE AR G36LMLE ...
Page 40: ...DTR_AO135E_01 2013 02 28 SINGLE TYPE AO G30LETL AO G36LETL 2 OUTDOOR UNIT ...
Page 46: ... 02 05 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL MODEL AO G36LETL ...
Page 51: ... 02 10 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL SOUND LEVEL CHECK POINT 88888 ...