- (02 - 01) -
O
U
TD
O
O
R U
N
IT
AO
G
12
-1
8L
A
O
U
TD
O
O
R U
N
IT
AO
G
12
-1
8L
A
SPECIFICATIONS
1.
Type
INVERTER HEAT PUMP
Model name
AO
G12LALL
AO
G14LALL
AO
G18LALL
Power sourse
230V ~ 50Hz
Available voltage range
198 - 264V ~ 50Hz
Starting current
A
5.1
6.1
7.4
Fan
Airflow rate
Cooling
m
3
/h
1780
1910
2000
Heating
1630
1740
1910
Type × Q'ty
Propeller × 1
Motor output
W
54
Sound pressure level
Cooling
dB (A)
47
49
50
Heating
48
49
50
Heat exchanger type
Dimensions
(H × W × D)
mm
546 × 876 × 18.2
546 × 842 × 18.2
Fin pitch
1.30
Rows × Stages
2 × 26
Pipe type
Copper
Fin Type
Aluminium
Compressor
Type × Q'ty
Twin Rotary × 1
Motor output
W
1100
Refrigerant
Type
R410A
Charge
g
1150
1250
Refrigerant oil
Type
POE
Enclosure
Material
Steel sheet
Colour
Beige (10YR7.5 / 1.0NN)
Dimensions
(H × W × D)
Net
mm
578 × 790 ×300
Gross
648 × 910 × 380
Weight
Net
kg
40 (88)
Gross
44 (97)
Connenction pipe
Size
Liquid
mm
Ø6.35 (Ø1/4 in.)
Gas
Ø9.52 (Ø3/8 in.)
Ø12.70 (Ø1/2 in.)
Method
Flare
Pre-charge length
m
15
Max. length
25
Max. height difference
15
Operation range
Cooling
°C
-10 to 46
Heating
-15 to 24
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB / 24 °CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB / 6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
The maximum current is the maximum value when the operated within the operation range (temperature).
The protective function might work when using it outside the operation range.