OPERATION DETAILS

Please read and understand the following details regarding this air conditioner.

Operation and Performance

Heating Performance

This air conditioner uses a heat pump which absorbs
heat from outside air and brings it indoors. As a result, its
heating performance is reduced as the temperature of
outside air drops. If you find that insufficient room heat
is produced, we recommend that you use the air
conditioner together with other heating appliances.

Heat-pump type air conditioners use warm-air recircula-
tion to warm your entire room. As a result, some time
will be required after starting operation until your entire
room becomes warm.

Microcomputer-controlled Automatic
Defrosting

When outside air temperatures are low and humidity is high,
using the Heating mode may result in the creation of frost
inside the outdoor unit, lowering its heating performance.
A built-in microcomputer is used to monitor this condition
and when necessary, the defrosting mode operates, result-
ing in a temporary interruption of the Heating mode (both
indoor and outside fans will stop). About 7 to 15 minutes
will be required for normal operation to be resumed.

Temperature and Humidity Range

Permissible ranges of temperature and humidity are as
follows:

Outdoor temperature:
About 21°C to 43°C

Indoor temperature:
About 21°C to 32°C

Indoor humidity:
About 80% or less. If the unit is used for
long periods under conditions of high
humidity, water may condense on and drip
from the surface of the unit.

Outdoor temperature:
About 0°C to 21°C

Indoor temperature:
About 30°C or less

If the unit is used under higher temperature conditions
than those noted here, the automatic protection circuit may
operate, interrupting the operation. If the unit is used under
lower temperature conditions than those noted here, the heat
exchanger may freeze, causing water leakage or other
malfunction.

Do not use the air conditioner for any purpose other
than room cooling or room heating.

Cooling

Operation

Heating

Operation

Summary of Contents for AKY12U

Page 1: ...ERSE CYCLE MODEL AMY12U OPERATING MANUAL ROOM AIR CONDITIONER WINDOW TYPE OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED ...

Page 2: ...ns no user serviceable parts When moving consult authorized service personnel for disconnection and installation of the unit PRECAUTIONS 2 NAME AND FUNCTION OF PARTS 6 AIR CONDITIONER OPERATION 7 AIR DIRECTION ADJUSTMENT 10 CARE AND MAINTENANCE 13 TROUBLESHOOTING 14 OPERATION DETAILS 15 PRECAUTIONS Before using the appliance read these PRECAUTIONS thoroughly and operate in the correct way The inst...

Page 3: ...wer cord Do not stand heavy items on the power cord or allow it to be pulled Such treatment could damage the insulation resulting in fire hazard and electrical shock WARNING If the power supply cord of this air conditioner is damaged it must be replaced by the manufacturer or its authorized service personnel only in order to avoid a safety hazard In the event of a malfunction burning smell etc imm...

Page 4: ...The quality of the stored items may deteriorate Do not direct air flow at fireplaces or heating apparatuses Direct air blowing on fires could result in improper combustion or fire Do not set flower vases or water containers on top of air conditioners Water leaking inside the unit could damage electrical insulation leading to danger of electrical shock Do not operate the air conditioner with wet ha...

Page 5: ...nd possible damage Do not use inflammable gases near the air conditioner Do not touch the heat exchanger radiator fins Personal injury could result Be particularly careful when cleaning Bending or damage to the fins will affect the efficiency of the unit When installing the air conditioner take precautions to prevent access by infants Unexpected accidents could occur Avoid installing the air condi...

Page 6: ...ken in here 7 Air Filter P 13 Removes all dirt and dust from the air Control Panel 1 SELECT Lever NEUTRAL When changing the airflow by manual ope ration SUPER WAVE ZONE When SUPER WAVE is operated adjust to the desired air flow direction P 11 2 SUPER WAVE Switch OFF When the air conditioner is operated by one direction airflow ON When taking out the airflow in the widerange 3 EXHAUST AIR Lever CLO...

Page 7: ...ts maximum resulting in maximum cooling effect Cooling To obtain maximum cooling effect in the hot summer select position HIGH POWER on the master control Maximum moisture removal air circulation and dust removal are effected at the same time Selection of SUPER QUIET reduces operating noise Air Circulation To maintain a comfortable room temperature an important factor is the circulation of air Roo...

Page 8: ...hen operating with the MASTER CONTROL switched to HIGH POWER RED or SUPER QUIET RED turn the thermostat fully clockwise 2 When operating with the MASTER CONTROL switched to HIGH POWER BLUE or SUPER QUIET BLUE turn the thermostat fully counterclockwise Power Supply Cooling To obtain maximum cooling effect in the hot summer select position HIGH POWER BLUE on the MASTER CONTROL Maximum moisture remov...

Page 9: ...numbers NOTE When the THERMOSTAT Control switch is set at positions 5 6 or 7 comfortable room temperatures can usually be obtained Please note that it is unhealthy for the room temperature to be lower than approximately 22 C When the THERMOSTAT Control switch is set at positioned at 10 the room side fin coil may freeze up and prevent effective cooling If this happens turn the switch to FAN and tur...

Page 10: ...by manual operation Horizontal Adjustment The Right Left Airflow direction Louvres may be positioned using tabs to dis charge the air rightward leftward or straight on NOTE The THERMOSTAT positions 8 9 and 10 can be used when the room temperature does not become sufficiently low This condition may occur when the THERMOSTAT Control switches off automatically because cooled air when it passes throug...

Page 11: ... Set the SUPER WAVE Switch to ON NOTE If the MASTER CONTROL Switch is set to set it to the other position 4 The sweep angle can be adjusted within the SUPER WAVE ZONE range When the SELECT LEVER is moved to the right or left the sweep angle decrease or increase NOTE If the SELECT LEVER is returned to the NEUTRAL in error the Right Left Airflow direction Louvres do not function properly In this eve...

Page 12: ...entre Right Side Lightly move the Right Left Airflow direction Louvres to the left until they stop Position the Right Left Airflow direction Louvres approx at the centre Lightly move the Right Left Airflow direction Louvres to the right until they stop CAUTION Adjust the Right Left Airflow direction Louvres after SELECT LEVER is set to the NEUTRAL position AIR DIRECTION ADJUSTMENT Minimum Maximum ...

Page 13: ...nit by wiping with a cloth dipped in cool or warm water then wipe with another soft clean dry cloth CAUTION Never use water that is hotter than 40 C The body may warp or change colour Do not use inflammable sprays such as lacquer or hair spray near the air conditioner The unit can be damaged by gasoline benzine thinners insecticides and other chemical agents When Not Using the Unit for Extended Pe...

Page 14: ...er During Cooling operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the fan may stop and steam may be seen rising from the unit This is due to operation of the defrosting mode REVERSE CYCLE MODEL During Heating mode the unit will t...

Page 15: ...omputer is used to monitor this condition and when necessary the defrosting mode operates result ing in a temporary interruption of the Heating mode both indoor and outside fans will stop About 7 to 15 minutes will be required for normal operation to be resumed Temperature and Humidity Range Permissible ranges of temperature and humidity are as follows Outdoor temperature About 21 C to 43 C Indoor...

Reviews: