Drain installation

21 21 

 CAUTION

Perform drain work in accordance with this Manual, and ensure that the drain water 

is properly drained. If the drain work is not carried out correctly, water may drip down 

from the unit, wetting the furniture.

When the outdoor temperature is 32 °F or less, do not use the accessory drain pipe 

and drain cap. If the drain pipe and drain cap are used, the drain water in the pipe may 

freeze in extremely cold weather. (Reverse cycle model only)

Outdoor unit to be fasten with bolts at the four places indicated by the arrows without fail.

Bottom side

Drain cap mounting place

Drain pipe mounting place

Since  the  drain  water  flows  out  of  the  outdoor  unit  during  heating  operation,  install  the 

drain  pipe  and  connect  it  to  a  commercial  16  mm  (5/8  in.)  hose.  (Reverse  cycle  model 

only)

When installing the drain pipe, plug all the holes other than the drain pipe mounting hole 

in the bottom of the outdoor unit with putty so there is no water leakage. (Reverse cycle 

model only)

               

Drain pipe mounting hole

Base

Drain pipe

Installation dimensions

21 21 

 CAUTION

Install the unit where it will not be tilted by more than 3˚. However, do not install the 

unit with it tilted towards the side containing the compressor.

When installing the outdoor unit where it may exposed to strong wind, fasten it 

securely.

Decide the mounting position with the customer as follows:

(1) Install the outdoor unit in a location which can withstand the weight of the unit and 

vibration, and which can install horizontally.

(2) Provide the indicated space to ensure good airflow.

(3) If possible, do not install the unit where it will be exposed to direct sunlight.

 (If necessary, install a blind that does not interfere with the airflow.)

(4) Do not install the unit near a source of heat, steam, or flammable gas.

(5) During heating operation, drain water flows from the outdoor unit.

Therefore, install the outdoor unit in a place where the drain water flow will not be 

obstructed. (Reverse cycle model only)

(6) Do not install the unit where strong wind blows or where it is very dusty.

(7) Do not install the unit where people pass.

(8) Install the outdoor unit in a place where it will be free from being dirty or getting wet by 

rain as much as possible.

(9) Install the unit where connection to the indoor unit is easy.

Single outdoor unit installation

21 21 11 

When the upward area is open

 

• When there are obstacles at the back side.

100 mm (4 in.)

or more

INSTALLATION WORK

21 

Please obtain the approval of the customer when selecting the location of installation 

and installing the unit.

Selecting an installation location

21 11 

 WARNING

Securely install the outdoor unit at a location that can withstand the weight of the unit. 

Otherwise, the outdoor unit may fall and cause injury.

Be sure to install the outdoor unit as prescribed, so that it can withstand earthquakes 

and typhoons or other strong winds. Improper installation can cause the unit to topple 

or fall, or other accidents.

Do not install the outdoor unit near the edge of a balcony. Otherwise, children may 

climb onto the outdoor unit and fall off of the balcony.

 CAUTION

Do not install the outdoor unit in the following areas:

Area with high salt content, such as at the seaside. It will deteriorate metal parts, 

 

causing the parts to fail or the unit to leak water.

Area filled with mineral oil or containing a large amount of splashed oil or steam, 

 

such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the 

unit to leak water.

Area that generates substances that adversely affect the equipment, such as 

 

sulfuric gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed 

joints to corrode, which can cause refrigerant leakage.

Area containing equipment that generates electromagnetic interference. It will 

 

cause the control system to malfunction, preventing the unit from operating 

normally.

Area that can cause combustible gas to leak, contains suspended carbon fibers or 

 

flammable dust, or volatile inflammables such as paint thinner or gasoline. If gas 

leaks and settles around the unit, it can cause a fire.

Area that has heat sources, vapors, or the risk of the leakage of flammable gas in 

 

the vicinity.

Area where small animals may live. It may cause failure, smoke or fire if small 

 

animals enter and touch internal electrical parts.

Area where animals may urinate on the unit or ammonia may be generated.

 

Please install the outdoor unit without slant.

Install the outdoor unit in a well-ventilated location away from rain or direct sunlight.

If the outdoor unit must be installed in an area within easy reach of the general public, 

install as necessary a protective fence or the like to prevent their access.

Install the outdoor unit in a location that would not inconvenience your neighbors, as 

they could be affected by the airflow coming out from the outlet, noise, or vibration. If it 

must be installed in proximity to your neighbors, be sure to obtain their approval.

If the outdoor unit is installed in a cold region that is affected by snow accumulation, 

snow fall, or freezing, take appropriate measures to protect it from those elements. To 

ensure a stable operation, install inlet and outlet ducts.

Install the outdoor unit in a location that is away from exhaust or the vent ports that 

discharge vapor, soot, dust, or debris.
Install the indoor unit, outdoor unit, power supply cable, connection cable, and remote 

control cable at least 1 m (40 in.) away from a television or radio receivers. The 

purpose of this is to prevent TV reception interference or radio noise. (Even if they are 

installed more than 1 m (40 in.) apart, you could still receive noise under some signal 

conditions.)

Branch switch and 

circuit breaker

Branch switch and 

circuit breaker

1 m (40 in.) or more

1 m (40 in.) or more

If children under 10 years old may approach the unit, take preventive measures so 

that they cannot reach the unit.

Keep the length of the piping of the indoor and outdoor units within the allowable 

range.

For maintenance purposes, do not bury the piping.

9374747122_IM_En.indd   5

20/12/2553   13:09:06

Summary of Contents for AIR CONDITIONER

Page 1: ...TIONER OUTDOOR UNIT PART NO 9374747122 INSTALLATION MANUAL For authorized personnel only MANUEL D INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado 9374747122_IM_En indd 1 20 12 2553 13 09 04 ...

Page 2: ...ly refrigeration compressor oil or equivalent used for the outdoor unit to the matching surfaces of the flare and union tubes before connecting them then tighten the nut with a torque wrench for a leak free connection Check carefully for leaks before starting the test run NOTE Depending on the system type liquid and gas lines may be either narrow or wide Therefore to avoid confusion the refrigeran...

Page 3: ... water etc does not enter the piping than with refrigerant models Also when storing the piping securely seal the openings by pinching taping etc When charging the refrigerant take into account the slight change in the composition of the gas and liquid phases and always charge from the liquid phase side whose composition is stable Special tools for R410A 222222 Tool name Contents of change Gauge ma...

Page 4: ...capacity type 222222222 CAUTION The total capacity of the indoor units connected must be between 14 000 and 27 000 BTU Connection patterns are restricted Normal operation is not guaranteed if connected pattern in the combination not listed below The product may be damaged Surely connect in accordance with the combination in the following connection pattern To install an indoor unit refer to the in...

Page 5: ...ng is neces sary For more information refer to 6 2 Additional charging Selecting pipe sizes 222222222 The diameters of the connection pipes differ according to the capacity of the indoor unit Refer to the following table for the proper diameters of the connection pipes between the indoor and outdoor units Capacity of indoor unit Gas pipe size thickness mm in Liquid pipe size thickness mm in 7 12 ø...

Page 6: ...topple or fall or other accidents Do not install the outdoor unit near the edge of a balcony Otherwise children may climb onto the outdoor unit and fall off of the balcony CAUTION Do not install the outdoor unit in the following areas Area with high salt content such as at the seaside It will deteriorate metal parts causing the parts to fail or the unit to leak water Area filled with mineral oil o...

Page 7: ...pipes Secure the unit to a solid block using foundation bolts Use 4 sets of commercially available M10 bolts nuts and washers The bolts should protrude 20 mm 0 78 in Refer to the figure If overturning prevention is required purchase the necessary commercially available items Unit mm in 650 25 19 32 370 14 9 16 Bottom side 4 ø12 1 15 32 hole Fix securely with bolts on a solid block Use 4 sets of co...

Page 8: ...er and flare tool exclusive for R410A 1 Cut the connection pipe to the necessary length with a pipe cutter 2 Hold the pipe downward so that the cuttings will not enter the pipe and remove any burrs 3 Insert the flare nut always use the flare nut attached to the indoor and outdoor units respectively onto the pipe and perform the flare processing with a flare tool Leakage of refrigerant may result i...

Page 9: ...ngth may lead to erroneous operation The static electricity that is charged to the human body can damage the control PC Board when handling the control PC Board for address setting etc Please keep caution to the following points Provide the grounding of Indoor unit Outdoor unit and Option equipment Cut off the power supply breaker Touch the metal section such as the unpainted control box section o...

Page 10: ... UNIT A DISCONNECT SWITCH FIELD SUPPLY DISCONNECT SWITCH FIELD SUPPLY WARNING Disconnect switch and for over current protection given in the table below is to be installed between the indoor unit and the outdoor unit Disconnect switch 15A CAUTION Be sure to refer the above diagram and do correct field wiring Wrong wiring causes malfunction of the unit Check local electrical codes and also any spec...

Page 11: ...ps and charging port cap of the 2 way valve and 3 way valve to the specified torque Checking gas leaks with nitrogen gas Check if the piping connections are secure Remove the cap of 3 way valve and connect the gauge manifold charge hoses to the charging port of the 3 way valve Pressurize with nitrogen gas using the 3 way valve charging port Do not pressurize up to the specified pressure all at onc...

Page 12: ...ng the refrigerant take into account the slight change in the composition of the gas and liquid phases and always charge from the liquid phase side whose composition is stable Gas Liquid R410A Add refrigerant from the charging valve after the completion of the work If the units are further apart than the maximum pipe length correct operation cannot be guaranteed POWER 777 WARNING The rated voltage...

Page 13: ...D2 LED1 Hole LED is on a reverse side of the board Confirming the operation of indoor unit 888888 Run the unit in a normal way and confirm its operation Please end the test run first before confirmation 1 Cold air or warm air must be discharged from the indoor unit 2 The indoor unit operates normally when air direction or air volume adjustment buttons pressed PUMP DOWN 999 PUMP DOWN OPERATION To a...

Page 14: ...9374747122_IM_Es indd 13 20 12 2553 13 13 45 ...

Page 15: ...9374747122_IM_Es indd 14 20 12 2553 13 13 45 ...

Page 16: ...9374747122_IM_Es indd 15 20 12 2553 13 13 45 ...

Reviews: