Vertical Air Direction Adjustment
Press the SET button (Fig. 5
L
).
Each time the button is pressed, the air direction range will change as follows:
1
2
3
4
5
6
Types of Air
fl
ow Direction Setting:
1, 2, 3, 4, 5, 6 : During Heating/Cooling/Dry modes
The Remote Controller's display does not change.
●
Use the air direction adjustments within the ranges shown above.
●
The vertical air
fl
ow direction is set automatically as shown, in accordance with the
type of operation selected.
During Cooling/Dry mode : Horizontal
fl
ow 1
During Heating mode
: Downward
fl
ow 6
●
During AUTO mode operation, for the
fi
rst a few minutes after beginning operation,
air
fl
ow will be horizontal 1; the air direction cannot be adjusted during this period.
The
air
fl
ow direction setting will temporarily become 1 when the temperature of the
air
fl
ow is low at the start of the Heating mode.
Right-Left Adjustment
Adjust the Right-Left louvers.
●
Move the Right-Left louvers to adjust air
fl
ow in the direction you prefer.
knob(two places)
Right-Left Louvers
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Vertical (up-down) direction of air
fl
ow is adjusted by pressing the Remote Controller's SET button. Horizontal (right-left) air
fl
ow direc-
tion is adjusted manually, by moving the Air
fl
ow Direction Louvers.
Whenever making horizontal air
fl
ow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are
stopped.
DANGER!
●
Never place fingers or foreign objects in-
side the outlet ports, since the internal fan
operates at high speed, and personal injury
could be caused.
●
Always use the Remote Controller's SET
button to adjust the vertical air
fl
ow lou-
vers. Attempting to move them manually
could result in improper operation; in this
case, stop operation and restart. The
louvers should begin to operate properly
again.
●
During use of the Cooling and Dry
modes, do not set the Air
fl
ow Direction
Louvers in the Heating range (4 - 6)
for many hours, since water vapor may
condense near the outlet louvers and
drops of water may drip from the indoor
unit. During the Cooling and Dry modes,
if the Airflow Direction Louvers are left
in the heating range for more than 30
minutes, they will automatically return to
position 3.
●
When used in a room with infants, chil-
dren, elderly or sick persons, the air
fl
ow
direction and room temperature should
be considered carefully when making
settings.
CAUTION!
●
When adjusting the Right-Left Louvers, it
is necessary to stop the Vertical (up-down)
louvers first and make sure that it stops
completely before adjusting the direction.
1
2
3
4
5
6
knob
En-10