TROUBLESHOOTING

Symptom

Problem

See Page

NORMAL 

FUNCTION

Does not operate immedi-
ately:

 

  If the unit is stopped and then immediately started again, the com-

pressor will not operate for about 3 minutes, in order to prevent fuse 
blowouts.

 

  Whenever the electrical breaker is turned off then on again, the protec-

tion circuit will operate for about 3 minutes, preventing unit operation 
during that period.

Noise is heard:

 

  During operation and immediately after stopping the unit, the sound 

of water 

fl

 owing in the air conditioner’s piping may be heard. Also, 

noise may be particularly noticeable for about 2 to 3 minutes after 
starting operation (sound of coolant 

fl

 owing).

 *

 

During heating operation, a sizzling sound may be heard occasionally. 
This sound is produced by the automatic defrosting operation.

14

Smells:

 

  Some smell may be emitted from the indoor unit. This smell is the 

result of room smells (furniture, tobacco, etc.) which have been taken 
into the air conditioner.

Mist or steam are emitted:

 

  During cooling or dry operation, a thin mist may be seen emitted from 

the indoor unit. This results from the sudden cooling of room air by 
the air emitted from the air conditioner, resulting in condensation and 
misting.

 *

 

During heating operation, the outdoor unit’s fan may stop, and steam 
may be seen rising from the unit. This is due to the automatic defrost-
ing operation.

14

Air

fl

 ow is weak or stops:

 *

  When heating operation is started, fan speed is temporarily very low, 

to allow internal parts to warm up.

 *

 

During heating operation, if the room temperature rises above the 
thermostat setting, the outdoor unit will stop, and the indoor unit will 
operate at very low fan speed. If you wish to warm the room further, 
set the thermostat to a higher setting.

 *

 

During heating operation, the unit will temporarily stop operation (be-
tween 4 and 15 minutes) as the automatic defrosting mode operates. 
During the automatic defrosting operation, 

 will be shown on the 

remote controller display.

14

 

  The fan may operate at very low speed during dry operation or when 

the unit is monitoring the room’s temperature.

 

 In the monitor AUTO operation, the fan will operate at very low 

speed.

Water is produced from the 
outdoor unit:

 *

 During heating operation, water may be produced from the outdoor 

unit due to the automatic defrosting operation.

14

The FILTER indicator 
blinks:

 

 Clean the 

fi

 lter. Afterwards, turn the FILTER indicator off.

12

  thermo sensor display 

on the remote controller is 

fl

 ashing:

 

  The room temperature sensor may be malfunctioning. Please consult 

authorized service personnel.

CHECK ONCE

MORE

Does not operate at all:

 

  Has the circuit breaker been turned off?

 

  Has there been a power failure?

 

  Has a fuse blown out, or a circuit breaker been tripped?

 

  Is the timer operating?

Poor cooling (or heating*) 
performance:

 

  Is the air 

fi

 lter dirty?

 

  Are the air conditioner’s intake grille or outlet port blocked?

 

  Did you adjust the room temperature settings (thermostat) correctly?

 

  Is there a window or door open?

 

  In the case of cooling operation, is a window allowing bright sunlight 

to enter? (Close the curtains.)

 

  In the case of cooling operation, are there heating apparatus and com-

puters inside the room, or are there too many people in the room?

If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, disconnect the power 
supply, and consult with authorized service personnel.

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

9374379552-02_OM.indb   Sec2:13

9374379552-02_OM.indb   Sec2:13

2012/3/29   下午 04:47:30

2012/3/29   下午 04:47:30

Summary of Contents for ACY140HUIAT-LH

Page 1: ...Türkçe 中國語 KEEP THIS MANUAL FOR FUTURE REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA CONSULTA FUTURA РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU DAHA SONRA BAŞ...

Page 2: ...on at least 12 hours before starting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at l...

Page 3: ...URES AND FUNCTIONS Convenient function WEEKLY TIMER Use this timer function to set operating times for each day of the week Use the DAY OFF setting to switch off timed opera tion for a selected day in the coming week Because all days can be set together the weekly timer can be used to repeat the timer settings for all of the days TEMPERATURE SET BACK TIMER Use this timer function to change the set...

Page 4: ...tion lamp F Timer and Clock indicator G Operation mode indicator H Fan speed indicator I Operation lock indicator J Temperature indicator K Function indicator Defrost indicator Thermo sensor indicator ECONOMY indicator Vertical swing indicator 3 Filter indicator 1 1 3 These functions cannot be used Please also see the operating manual of the option when using it with options etc 1 Can be used if s...

Page 5: ...set the current time Press repeatedly to adjust the current time in 1 minute incre ments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK Set the current day and time 9374379552 02_OM ind...

Page 6: ...o set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY opera tion For details on the function refer to page 12 To start stop operation To set the operation mode Operation mode setting Room temperature setting Fan speed setting ECONOMY operation AUTO COOL DRY FAN HEAT AUTO HIGH MED LOW Instructions relating to heating are applicable on...

Page 7: ...he DAY DAY OFF button and TIMER SET button simul taneously for 2 seconds or more to activate the child lock func tion and lock all of the buttons on the remote controller except the START STOP button SET TEMP buttons MODE button and FAN button Press the buttons again for 2 seconds or more to deactivate the child lock function When the child lock function is activated the mark ap pears If any butto...

Page 8: ... passed The timer can be set up to 24 hours in advance ON timer See page 8 Use this timer function to start air conditioner operation The timer operates and air conditioner operation starts after the set time has passed The timer can be set up to 24 hours in advance WEEKLY timer See page 9 Use this timer function to set operating times for each day of the week Use the DAY OFF setting to switch off...

Page 9: ...n to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more To delete the operating time If the TIMER DELETE button is pressed dur ing steps 3 or 4 the operating time for the selected day will be deleted If all the days are selected the operating times for all of the d...

Page 10: ...FF setting 2 4 3 To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below Normal Next day setting The DAY OFF setting can only be set 1 time Th...

Page 11: ... setting all days together Temperature setting Press the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings 24 C 24 C 28 C SET BACK temperature Normal temperature To start SET BAC...

Page 12: ...y and increasing noise CAUTION ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator will go out Normal operation begins About ECONOMY Operation At the maximum output ECONOMY o...

Page 13: ... to warm up During heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the thermostat to a higher setting During heating operation the unit will temporarily stop operation be tween 4 and 15 minutes as the automatic defrosting mode operates During the a...

Page 14: ...oller can control the air conditioner However the timer functions cannot be used at the slave unit Group Control One remote controller can control up to 16 air conditioners All of the air conditioners will be operated with the same settings Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the...

Page 15: ...mode or dry mode Room temperature is close to the defined temperature in temperature set ting Determined by outdoor temperature Room temperature is lower than the defined temperature in temperature setting Heating mode When AUTO automatic changeover is selected the air conditioner selects the appropriate operation mode cooling or heating according to your room s present temperature When AUTO autom...

Page 16: ... when it is stopped it is not a malfunction During use of the heating mode the outdoor unit will oc casionally commence the defrost operation for brief periods During the defrosting operation if the user sets the indoor unit for heating again the defrosting mode will continue and the heating operation will begin after completion of defrosting with the result that some time may be required before w...