CLEANING AND CARE

Cleaning the Air Filter

1. Pull out both sides and the center of the 

intake grille.

About 30 mm

Side Panel

Intake Grille

Notch

Arm

Hook

Arm

2. Pull the air 

fi

 lters upward to remove them.

 

Push the air 

fi

 lter handles away from the intake grille in di-

rection [A], then pull out the air 

fi

 lters.

Handle

Intake Grille

Base

[A]

Air Filter

Bracket

3. Clean the air 

fi

 lters.

 

Remove the dust from the air 

fi

 lters by vacuuming or wash-

ing them. After washing, allow the air filters to dry thor-
oughly in an area protected from sunlight.

4. Re-attach the air 

fi

 lters to the intake grille.

(1) The air 

fi

 lters 

fi

 t onto the inside of the intake grille. (Figure 1)

(2) The bottom edges of the air 

fi

 lters should 

fi

 t into the 

fi

 lter 

brackets. (Figure 1)

(3) The  air 

fi

 lters should be pushed down so that their top 

edges 

fi

 t under the projections at the top of the intake 

grille. (Figure 2)

(Figure 1)

Filter bracket

Air Filter

(Figure 2)

5. Push in both sides and the center of the 

intake grille.

  Dust can be cleaned from the air 

fi

 lter either with a vacuum 

cleaner, or by washing the 

fi

 lter in a solution of mild deter-

gent and warm water. If you wash the 

fi

 lter, be sure to allow 

it to dry thoroughly in a shady place before reinstalling.

  If dirt is allowed to accumulate on the air 

fi

 lter,  air 

fl

 ow  will 

be reduced, lowering operating efficiency and increasing 
noise.

Filter Reset (ECONOMY indicator lamp 

fl

 ashing/ The special setting)

  

Can be used if set correctly during installation. 

Please consult authorized service personnel when using this 

function.

•  It lights on when it is time to clean the air 

fi

 lters.

After turning the power on, press the MANUAL AUTO button 
for 2 seconds or less on the indoor unit.

: Flashing

: OFF

  Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cable.

  Be sure the intake grille is installed securely.

  When removing and replacing the air 

fi

  lters, be sure not to touch the heat exchanger, as personal 

injury may result.

 CAUTION

  When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit 

be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.

  When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.

  Do not expose the unit body to liquid insecticides or hairsprays.

 

If the unit will not be operated for a period of 1 month or more, be sure to allow the inner parts of the unit to dry thoroughly, 
in advance, by operating the unit in fan mode for half a day.

9374379729_OM.indb   14

9374379729_OM.indb   14

24/06/2013   09:41:19

24/06/2013   09:41:19

Summary of Contents for ABYG18LVTB

Page 1: ...ABYG18LVTB ABYG24LVTA Floor CeilingType OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE PART No 9374379729 English ...

Page 2: ...unit for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or chang ing the air filter Connection valves become hot during Heating handle with care When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Check the condition of the installation stand for damage Do not place animals or...

Page 3: ...an function REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance Remote controller WIRELESS REMOTE CONTROLLER The wireless remote controller allows convenient control of air conditioner operation WIRED REMOTE CONTROLLER OPTION The optional wired remote controller can be used When you use remote controller there are following different points as ...

Page 4: ...chance press the START STOP button to stop the operation Please press the button at Filter Reset 3 Remote control signal receiver 4 OPERATION indicator lamp green 5 TIMER indicator lamp orange TIMER indicator lamp lights when the timer is set from wireless remote controller 6 ECONOMY indicator lamp green ECONOMY indicator lamp lights when ECONOMY operation and 10 C HEAT operation is operating 7 In...

Page 5: ... conditioner s thermostat function to operate incorrectly If this button is pressed during normal op eration the unit will switch to test run mode and the indoor unit s OPERATION indicator lamp and TIMER indicator lamp will begin to flash simultaneously To stop the test run press the START STOP button to stop the air conditioner F Signal transmitter G Temperature SET indicator H Operating mode ind...

Page 6: ...id on the reverse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time button...

Page 7: ... button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches t...

Page 8: ...select the appropriate operation heating cooling to adjust the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation HEAT COOL DRY FAN HEAT Use to warm your room When heating mode is selected the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the ...

Page 9: ...ime indicator is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light 2 Set the desired times for OFF timer an...

Page 10: ...Set time 1 hour 1 C 2 C 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is automati cally raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is main tained until the set time has elapsed at which time the air condi tioner automatically turns off S...

Page 11: ...th the air direction buttons on the Remote Controller Use the air direction buttons after the Indoor Unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Airflow Direction Setting 1 2 3 4 During cooling dry...

Page 12: ...ner s fan is not operating or when operating at very low speeds To select up down swing operation ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green wi...

Page 13: ...ntact your retailer to set the individual air conditioner signal codes Selecting the Remote Controller Signal Code Indicator Lamp Lighting OFF If no buttons are pressed within 30 seconds after the signal code is displayed the system returns to the original clock dis play In this case start again from step 1 The air conditioner signal code is set to A prior to shipment Contact your retailer to chan...

Page 14: ... before reinstalling If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increasing noise Filter Reset ECONOMY indicator lamp flashing The special setting Can be used if set correctly during installation Please consult authorized service personnel when using this function It lights on when it is time to clean the air filters After turning t...

Page 15: ...room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emit ted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner result ing in condensation and misting During heating operation the outdoor unit s fan may stop and steam may be s...

Page 16: ...room by recir culating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of the heating mode the outdoor unit s fan may stop at times Microcomputer controlled Automatic Defrosting When using the heating mod...

Page 17: ...ferences of operating efficiency We rec ommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in the way that best matches your family s lifestyle If you discover that 1 or more units delivers a low level of cooling or heating during simultaneous operation we recommend that you stop simultaneous operation...

Page 18: ...oor unit even when it is stopped it is not a malfunction During use of the heating mode the outdoor unit will occa sionally commence the defrost operation for brief periods During the defrosting operation if the user sets the indoor unit for heating again the defrosting mode will continue and the heating operation will begin after completion of defrosting with the result that some time may be requ...

Reviews: