1-2. HEATING OPERATION
1-2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
The maximum frequency is limited in the range shown in Figure 2 based on the outdoor temperature.
* If the room temperature is lower 3 degC than a set temperature,
the compressor operation frequency will attain to maximum frequency.
* If the room temperature is higher 2.5 degC than a set temperature, the compressor
will be stopped.
* When the room temperature is b2.5 degC to -3 degC of the setting temperature,
the compressor frequency is controlled within the range shown in Table2.
( Table 2 : Compressor Frequency Range )
( Fig.2 : Limit of Maximum Frequency based on Outdoor Temperature )
01-02
Outdoor air
temperature
A zone
B zone
C zone
When the room
temperature rises
When the room
temperature drops
17°C
12°C
19°C
14°C
Hi
Me+
Me
Lo
Quiet
A zone
120Hz
120Hz
120Hz
101Hz
101Hz
70Hz
70Hz
113Hz
113Hz
60Hz
60Hz
70Hz
120Hz
120Hz
120Hz
101Hz
101Hz
75Hz
75Hz
101Hz
75Hz
60Hz
60Hz
60Hz
B zone
C zone
AB*F18, 24
AR*F18, 24
AU*F18, 24
A zone
B zone
C zone
AR*A24LATU
AU*A24LBL
Fan speed mode
minimum
frequency
maximum
frequency
AB*F18, 24
AR*F18, 24
AU*F18, 24
18Hz
120Hz
AR*A24LATU
AU*A24LBL
18Hz
120Hz