En-2

 WARNING

Do not modify this unit, such as opening a hole in the cabinet.

During the pump-down operation, make sure that the compressor is turned off before 
you remove the refrigerant piping.
Do not remove the connection pipe while the compressor is in operation with 2 way or 3 
way valve open. This may cause abnormal pressure in the refrigeration cycle that leads 
to rupture and even injury.

 CAUTION

This unit must be installed by quali

fi

 ed personnel with a capacity certi

fi

 cation of handling 

refrigerant 

fl

 uids. Refer to regulation and laws in use on installation place.

Install the unit by following local codes and regulations in force at the place of 
installation, and the instructions provided by the manufacturer.

This unit is part of a set constituting an air conditioner. The unit must not be installed 
alone or be installed with non-authorized device by the manufacturer.

When installing pipes shorter than 3 m, sound of the outdoor unit will be transferred to 
the indoor unit, which will cause large operating sound or some abnormal sound.

To protect the persons, earth( ground) the unit correctly, and use the power cable 
combined with an Earth Leakage Circuit Breaker (ELCB).

The units are not explosion proof, and therefore should not be installed in explosive atmosphere.

This unit contains no user-serviceable parts. Always consult experienced service 
technicians for repairing.

When moving or relocating the air conditioner, consult experienced service technicians 
for disconnection and reinstallation of the unit.

Children should be monitored to ensure they do not play with the device.

This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be supervised to ensure that they do 
not play with the appliance.

Do not touch the aluminum 

fi

 ns of heat exchanger built-in the indoor or outdoor unit to 

avoid personal injury when you install or maintain the unit.

Do not place any other electrical products or household belongings under indoor unit or 
outdoor unit. Condensation dripping from the unit might get them wet, and may cause 
damage or malfunction of your property.

2.  ABOUT THIS PRODUCT

•  All Fujitsu General products are manufactured to metric units and tolerances. 

United States customary units are provided for reference only. In cases where exact 
dimensions and tolerances are required, always refer to metric units.

2.1. Special tools for R410A

Tool name

Change from R22 to R410A

Gauge manifold

Pressure is high and cannot be measured with a conven-
tional (R22) gauge. To prevent erroneous mixing of other 
refrigerants, the diameter of each port has been changed.
It is recommended to use gauge with seals -0.1 to 5.3 MPa 
(-1 to 53 bar) for high pressure.
-0.1 to 3.8 MPa (-1 to 38 bar) for low pressure.

Charge hose

To increase pressure resistance, the hose material and base 
size were changed.(R410A)

Vacuum pump

A conventional vacuum pump can be used by installing a 
vacuum pump adapter.
(Use of a vacuum pump with a series motor is prohibited.)

Gas leakage detector

Special gas leakage detector for HFC refrigerant R410A.

Copper pipes

It is necessary to use seamless copper pipes and it is desirable that the amount of residual 
oil is less than 40 mg/10 m. Do not use copper pipes having a collapsed, deformed or 
discolored portion (especially on the interior surface). Otherwise, the expansion value or 
capillary tube may become blocked with contaminants.
As an air conditioner using R410A incurs pressure higher than when using R22, it is neces-
sary to choose adequate materials. 
Thicknesses of copper pipes used with R410A are as shown in Table1. Never use copper 
pipes thinner than 0.8 mm even when it is available on the market.

Thicknesses of Annealed Copper Pipes

Nominal diameter (in.)

Outer diameter (mm)

Thickness [mm(in.)]

1/4

6.35

0.80 (0.032)

3/8

9.52

1/2

12.7

 WARNING

To install a unit that uses R410A refrigerant, use dedicated tools and piping materials 
that have been manufactured speci

fi

 cally for R410A use. Because the pressure of 

R410A refrigerant is approximately 1.6 times higher than R22, failure to use dedicated 
piping material or improper installation can cause rupture or injury. Furthermore, it can 
cause serious accidents such as water leakage, electric shock, or 

fi

 re.

2.2. Power

 WARNING

Always use a special branch circuit and install a special receptacle to supply power to 
the room air conditioner.

Use a circuit breaker and receptacle matched to the capacity of the air conditioner.

Install a leakage circuit breaker in accordance with the related laws and regulations 
and electric company standards.

The circuit breaker is installed in the permanent wiring. Always use a circuit that can 
trip all the poles of the wiring and has an isolation distance of at least 3 mm between 
the contacts of each pole.

 CAUTION

The power source capacity must be the sum of the air conditioner current and the cur-
rent of other electrical appliances. When the current contracted capacity is insuf

fi

 cient, 

change the contracted capacity.
When the voltage is low and the air conditioner is dif

fi

 cult to start, contact the power 

company the voltage raised.

2.3. Electric requirement

 CAUTION

Be sure to install a breaker of the speci

fi

 ed capacity.

Regulation of cables and breaker differs from each locality, refer in accordance with 
local rules.

Voltage rating

1 ø 208/230 V (60 Hz)

Operating range

188-253 V

Cable

Type

Remarks

Power supply cable

14AWG UL 1505

2 cable + Earth (Ground), 

1 ø 208/230 V

Connection cable

14AWG UL 1505

3 cable + Earth (Ground), 

1 ø 208/230 V

Select the correct cable type and size according to the country or region’s regulations. 

Max. wire length: Set a length so that the voltage drop is less than 2%. Increase the wire 
diameter when the wire length is long.

 CAUTION

Outdoor unit capacity

9,12

15

MINIMUM CIRCUIT AMPACITY

14.4 A

18.2 A

MAX. CKT. BKR.

15 A

20 A

•  

 Before starting work check that power is not being supplied to all poles of the indoor 
unit and outdoor unit.

•  

Install all electrical works in accordance to the national standard.

•  

 Install the disconnect device with a contact gap of at least 3 mm in all poles nearby the 
units. (Both indoor unit and outdoor unit)

•  Install the circuit breaker nearby the units.

2.4. Pipe length

Pipe length

Max. height

Max.

Min.

66ft. (20m)

10ft. (3m)

49ft. (15m)

 CAUTION

If the pipe lengths and height differences are not kept as shown in the table, correct 
operation cannot be guaranteed.

The outdoor unit with the refrigerant removed from the packaging is sealed.
(Indoor unit, the refrigerant is not sealed.)

9379069649_IM.indb   2

9379069649_IM.indb   2

12/8/2014   2:04:44 PM

12/8/2014   2:04:44 PM

Summary of Contents for 9RLS3H

Page 1: ...rvicing Turn the power OFF at the main circuit breaker panel before opening the unit to check or repair electrical parts and wiring Keep your fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced After installation explain correct operation to the customer using th...

Page 2: ...r for HFC refrigerant R410A Copper pipes It is necessary to use seamless copper pipes and it is desirable that the amount of residual oil is less than 40 mg 10 m Do not use copper pipes having a collapsed deformed or discolored portion especially on the interior surface Otherwise the expansion value or capillary tube may become blocked with contaminants As an air conditioner using R410A incurs pre...

Page 3: ...door temperature Cooling Dry Mode About 14 to 115 F Heating Mode About 15 to 75 F 2 7 Accessories Installation manual 1 One set of following parts are necessary installation of this product Name Connection pipe assembly Decorative tape Saddle Tapping screws Connection cable Vinyl tape M10 bold nut Sealant Wall pipe Wall cap 3 SELECTING THE MOUNTING POSITION Decide the mounting position with the cu...

Page 4: ...will not be able to compress 1 Remove the tapping screw then remove the control box cover 2 Fasten the Inter unit wire harness and power supply to the conduit holder using the lock nut 3 Connect inter unit wire harness and power supply to the terminal 4 Use the tapping screw to install the control box cover NOTE Connector trade size for this unit is 1 2 12 7 mm The connector can be bought at a har...

Page 5: ...ation in order to ensure compressor protection BENDING PIPES 1 When bending the pipe be careful not to crush it 2 To prevent breaking of the pipe avoid sharp bends Bend the pipe with a radius of curvature of 70 mm or over 3 If the copper pipe is bend the pipe or pulled to often it will become stiff Do not bend the pipes more than three times at one place Holding spanner 90 Body side Torque wrench ...

Page 6: ...nnot start if the MANUAL AUTO button is not kept on pressing for more than 10 sec onds 2 Close the valve stem of 2 way valve completely 3 Continue the forced cooling operation for 2 to 3 minutes then close all the valve stems on the 3 way valves 4 Stop the operation Press the START STOP button of the remote controller to stop the operation Press the MANUAL AUTO button when stopping the operation f...

Reviews: